Manufacturer of Linear Modules,Linear Motors,Electric Cylinders,Truss System!

Linear Motor Systems/Linear Motion/

  • Product Details

U Shape Ironless Linear Motor | UMA Series Direct Drive

Author: DeMing, Engineering Director | Published: 8th,Sept 2016| Category: Linear Motor Systems

A U-shape ironless linear motor drives its load with no screw, belt, rack or gearbox in the path. The coil assembly travels inside a U-shaped magnet channel, carrying nothing but its own windings and the epoxy that holds them, and the thrust it produces acts directly on the carriage.

What makes the U-channel geometry worth choosing is not thrust density — an iron-core motor of the same frame will always beat it there. It is what the geometry removes. Magnets face each other across the channel, so the attraction pulling the coil toward one wall is cancelled by the wall opposite. There is no slot structure in the forcer, so there is no position-periodic cogging force to correct. The consequences of those two facts run through the whole machine design, and this page works through them.

TechMan Robotics supplies UMA series U shape Ironless Linear Motor as separate forcers and magnet tracks for customer-designed stages, and as a pre-assembled U-shaped linear motor module with base, guide, table and feedback already integrated.

U-shaped ironless linear motor forcers and magnetic tracks

U-shaped ironless linear motor product family: forcers and magnetic tracks

How the U-Channel Geometry Works

The magnet track is an aluminium or steel channel with permanent magnets bonded to both inner faces, alternating in polarity along the length. A back yoke closes the magnetic circuit behind each magnet row, and spacer blocks join the two magnet plates at their ends, holding the rows rigidly apart and forming the open channel the coil runs in.

The forcer — referred to as the rotor in some supplier catalogues — is a flat, thin coil assembly potted in epoxy, suspended in the channel with clearance around it and rigid mounting only at its top face.

Three-phase current in the coil produces a field that interacts with the permanent field across the gap. Because the field crosses the coil from both directions, the resulting force is purely axial. The coil never touches the track, and nothing in the motor wears.

The pole pitch — magnet north-to-north spacing — is a number the servo drive needs during commutation setup. Across UMA range it is 30 mm on UMA22, 60 mm on UMA35 and UMA39, and 84 mm on UMA50.

U-shaped ironless linear motor working principle showing alternating magnet poles and the total air gap clearance

Working principle along the axis of travel. Adjacent magnets alternate in polarity along each stator row and each facing pair is opposite across the channel, so flux crosses the air gap in alternating directions as the forcer moves.

U channel ironless linear motor working principle coil magnet back yoke

Cross-section of a U-channel motor. The epoxy-cored coil runs between two opposing magnet rows, each backed by an iron yoke that closes the magnetic circuit.

ironless coil suspended inside U channel magnetic track

The ironless coil suspended inside the U-shaped magnetic track

Zero Attraction Force Changes the Guide Selection

An iron-core linear motor pulls on its magnet track continuously, often with a normal force several times its rated thrust. That load never goes away, it does not vary with duty, and the linear guide has to carry it on top of the payload for the life of the machine.

UMA technical tables list magnetic attraction as 0 kN for every model in the range. With the pull cancelled, the guide carries the payload, the process forces and nothing else. Rail size follows from the actual moment loads rather than from a permanent motor preload, bearing life calculations use the real duty cycle, and the machine base does not need extra stiffness to resist a force that is always present.

The same absence shows up in straightness of travel. On an iron-core axis, variation in the attraction force along the stroke feeds into the carriage as a varying normal load. Remove the attraction and the travel straightness is set by the rail and its mounting surface alone.

If your application needs the higher force density and you can accept the attraction load, the iron-core flat motor range is the better starting point — see the iron core flat linear motor page.

ironless linear motor forcer and U shaped magnetic track separated

Forcer and magnet track shown apart. The forcer carries windings and epoxy only, and with no ferromagnetic core it lifts out of the channel by hand.

The Air Gap Is Your Mounting Tolerance

This is the constraint that catches people moving from an iron-core motor or from a screw axis. The forcer hangs inside the channel without touching it, and it has to stay clear of both magnet faces over the entire stroke.

UMA dimensional drawings give the air gap as 0.7 mm on UMA22 and 1.0 mm on UMA35 through UMA50 — the clearance between the forcer and the stator. Everything in the tolerance stack has to fit inside that one number.

It is a small budget, and it is worth allocating before anything is machined. What consumes it:

  • flatness and parallelism of the surface the magnet track bolts to, over the full track length
  • straightness of the guide rail relative to the track axis
  • carriage-to-forcer bracket squareness, and its deflection under payload
  • track-to-track step and angular mismatch at every joint on a multi-segment stroke
  • thermal growth of the base between the track mounting and the rail mounting

None of this is peculiar — it is the same discipline used to align a long rail. What is different is that the tolerance stack is tighter than a mechanically driven axis needs, and none of it is recoverable in software. A screw axis with a misaligned rail runs badly; an ironless axis with a consumed air gap makes contact.

Machined mounting surfaces, a shared datum face for both track and rail, and dial-gauge verification of forcer position along the full stroke belong in the build procedure rather than in the commissioning notes. Our linear module quality control page covers the mounting-surface verification methods.

Reading the UMA Model Code in U shape Ironless Linear Motor

The code is fully descriptive, which makes the whole catalogue navigable without a lookup table:

UMA35-241-119 = frame size 35, coil length 241 mm, continuous thrust 119 N at self-cooled rating.

The pattern holds throughout. UMA22-61-19 is a 61 mm coil producing 19 N. UMA50-673-934 is a 673 mm coil producing 934 N. Longer coil, more magnet poles engaged, proportionally more thrust from the same current.

Frame

Coil lengths (mm) Continuous thrust, self-cooled (N) Peak thrust (N) Pole pitch (mm) Electrical time constant (ms)

Track weight (kg/m)

UMA22

31 – 241 9.5 – 76 47.5 – 380 30 0.2 3.93

UMA35

61 – 361 41 – 179 205 – 895 60 0.4

10.6

UMA39

61 – 361 47 – 209 235 – 1045 60 0.4

12.4

UMA50 85 – 673 118 – 934 590 – 4670 84 0.6

24.9

Peak thrust is five times continuous across the whole range, which is a useful final check when reading a model number back.

 

UMA series ironless linear motor forcers and tracks in four frame sizes

UMA series forcers and magnetic tracks across the frame sizes, shown side by side

Thermal Duty Decides the Coil Length in U shape Ironless Linear Motor

Continuous thrust on an ironless motor is a thermal rating, not a structural one. The coil dissipates I²R, the epoxy conducts it away, and the published continuous figure is the point at which the winding reaches its 100 °C limit from a 25 °C ambient.

The arithmetic is transparent and worth doing before selection. UMA22-31-9 dissipates 15.4 W at its continuous rating with K_thn of 0.2 W/°C, giving a 77 K rise — exactly the margin from 25 °C to the limit. UMA35-361-179 dissipates 163.3 W with K_thn of 2.1 W/°C, again 78 K. The relationship holds across the range, so a motor running at half its rated RMS current sits far cooler, and one in a sealed enclosure at 40 °C ambient has correspondingly less headroom.

Water cooling is offered on UMA35, UMA39 and UMA50, and the gain is substantial. UMA35-361-179 goes from 179 N self-cooled to 228.7 N. UMA50-673-934 goes from 934 N to 1027.4 N. Long cycles, high average thrust, restricted airflow or a warm enclosure all point toward the water-cooled variant.

The motor constant K_m (N/√W) is the number to compare when the application is thermally limited rather than peak limited, since it expresses thrust per unit of dissipated power. Across the UMA range it runs from roughly 9 N/√W on the shortest coils to about 26 N/√W on the longest — a coil that produces more thrust per watt reaches a given force with less heat, which is the whole selection question on a long-duty axis.

Magnet Track Lengths and Usable Stroke

Tracks are supplied in fixed segment lengths and butted end to end for longer travel.

Frame Segment options (mm)

Actual segment length (mm)

UMA22

120 / 180 / 300 119.7 / 179.7 / 299.7

UMA35, UMA39

120 / 180 / 300

119.5 / 179.5 / 299.5

UMA50 168 / 252 / 420

167.5 / 251.5 / 419.5

Usable stroke is total track length minus coil length, minus overtravel allowance at each end for the forcer bracket, cable carrier anchor and limit switches. A UMA22-61-19 on a single 300 mm track has under 239 mm of geometric travel before those allowances, so confirm the final figure against the mechanical layout rather than against the track length alone.

On multi-segment strokes the joints matter twice over. Magnet pitch has to stay continuous across the seam or commutation will disturb, and any step between segments comes straight out of the air gap described above — the same 0.7 or 1.0 mm that everything else is already drawing on.

Track weight also becomes a real number on long axes. UMA50 track runs 24.9 kg/m, so a 5 m stroke carries roughly 125 kg of stationary magnet assembly that the base has to support and locate.

U-shaped linear motor magnetic tracks in three standard lengths

Bare U-shaped magnetic tracks in three standard segment lengths

Feedback Scale Options in our U shape Ironless Linear Motor

A direct drive axis has no mechanical transmission to infer position from, so the scale determines the positioning performance of the finished axis. Both magnetic and optical scales are fitted to the UMA range, and the choice turns on the environment, the resolution the process needs and — less obviously — on speed, since a high-resolution reading head can cap the axis well below what the motor is capable of.

Scale types, the resolution-against-speed relationship, absolute versus incremental startup behaviour and mounting tolerances are covered in full on the linear motor feedback system page.

Servo Drive Sizing in our U shape Ironless Linear Motor

Continuous currents across the range are modest, from 1.6 Arms on the smallest UMA22 to 6.6 Arms on the largest water-cooled UMA50. Peak currents are not: they run four to five and a half times higher, so the drive is sized on peak rather than continuous and frequently lands several frames above what the continuous figure alone would suggest.

Drive platforms, commutation methods, peak current sizing worked through model by model, and the interface limits that decide which feedback can be used are covered on the linear motor drive page.

TechMan Robotics can supply motor and track as components for an existing drive, or specify the motor, feedback, guide and drive together as a matched axis.

U channel linear motor forcer and magnetic track supplied as components

A matched forcer and magnetic track pair supplied as components

Integrated U Shape Ironless Linear Motor

Where a complete axis is wanted rather than a motor to design around, the integrated module combines base, motor stator, wide-profile linear guide, aluminium moving table and optical scale in one assembly.

Parameter

Specification

Repeat positioning accuracy

±0.002 mm (module figure, with the supplied optical scale)

Continuous payload

4 kg

Maximum speed

2,500 mm/s

Continuous thrust

28 N

Peak thrust

75 N

Standard stroke

90 – 1,290 mm

Feedback

Integrated optical scale

Guide

Wide-profile linear guide

Magnetic attraction

Zero

Repeatability of this order is a property of the assembled axis rather than of the motor alone. It depends on the scale specified, its mounting, the thermal state of the base and the servo tuning. Quote it as a module specification and confirm it against the scale actually fitted to your order.

These module figures describe the integrated stage and do not correspond to any single UMA catalogue model. The two ranges are selected on different terms: the module by stroke and payload, the UMA components by thrust, coil length and thermal duty. Reading a UMA model number off the module specification, or the reverse, will produce the wrong part.

integrated U-shaped ironless linear motor module with guide and table

Integrated U-shaped ironless linear motor modules with guide, table and scale

Where the U-Channel Architecture Earns Its Place

Rather than a list of industries, it is more useful to look at motion signatures, because that is what decides whether this motor type fits.

Constant-velocity scanning. With no slot structure in the forcer there is no position-periodic cogging force for the servo loop to fight, so velocity holds steady through the sweep. Camera scanning, surface metrology, web inspection and line-scan imaging all depend on this, and it is the single characteristic that most often rules an iron-core motor out.

Short move, fast settle. The forcer is coil and epoxy only, so the mass being accelerated is small and the axis settles quickly after a move. Pick-and-place heads, die bonding, probe positioning and electronic component handling live in this regime, where cycle time is dominated by settling rather than by top speed.

Contact and force-sensitive work. With no attraction load in the guide and no transmission compliance between motor and payload, thrust commanded is close to thrust delivered. That makes the axis usable for controlled-force approach, dispensing at a held standoff, and probing.

Vacuum and clean environments. No lubricant in a drive train, no belt shedding particles, no screw to outgas. The motor itself contributes nothing to the particle count, which is why ironless axes appear in wafer handling and inspection tooling.

Where it does not fit: heavy vertical loads needing continuous holding thrust, high-force machining axes, and applications where an attraction load is acceptable in exchange for force density. Those belong on an iron-core or a screw-driven axis.

Selection Data We Need for selecting a U shape Ironless Linear Motor

Thrust alone will not size this motor. Send the motion profile and the mechanical context:

Motion — payload mass and its centre of gravity, stroke, move distance and move time, dwell between moves, maximum speed and acceleration, cycles per hour, and how many hours per day the axis runs.

Mechanical — mounting orientation, available envelope for the track and forcer, the surface the track will bolt to and its achievable flatness, and any external process force.

Performance — required repeatability and positioning accuracy, settling time, and whether constant-velocity smoothness or point-to-point speed is the governing requirement.

System — ambient temperature and whether cooling water is available, cleanliness and magnetic environment for the scale choice, existing servo drive if the motor is being retrofitted, and controller interface.

With that, our engineering team can work back to RMS thrust and coil temperature over the real duty cycle, then specify coil length, winding option, track configuration, scale and drive capacity together. Our linear module design page covers how custom axis projects run.

FAQ About a U shape Ironless Linear Motor

How accurately does the magnet track have to be mounted?

The air gap between forcer and stator is 0.7 mm on UMA22 and 1.0 mm on UMA35 through UMA50. Track mounting flatness, rail straightness, bracket squareness and thermal growth all draw on that one figure, so the budget should be allocated before machining rather than discovered at assembly.

Can strokes longer than one magnet track be built?

Yes. Segments butt end to end, and the constraint is joint quality: magnet pitch must remain continuous across the seam, and any step between segments consumes clearance that the rest of the tolerance stack has already claimed. On long UMA50 axes the track mass itself — nearly 25 kg per metre — becomes a base design consideration.

Should I order the series or the parallel winding?

Match it to the drive. Both give the same thrust; parallel halves the force constant and doubles the current, which suits a low-voltage drive with current capacity to spare. Parallel also halves back-EMF and so doubles the voltage-limited top speed, which is the deciding factor on the larger frames.

What actually limits the top speed?

Bus voltage against back-EMF, in most cases. Divide the 330 Vdc maximum bus by the motor’s K_e for an upper bound, then leave headroom, because accelerating at speed needs voltage the calculation does not account for. Scale read speed and mechanical resonance in the moving assembly can bind first on some builds.

Is water cooling necessary?

Only when the duty cycle says so. Work out RMS thrust over the real cycle, convert to dissipated power, divide by K_thn and add ambient. If the result approaches 100 °C, either move up a coil length or take the water-cooled variant.

Can this motor mount vertically?

Mechanically yes, but gravity acts on the load continuously and an ironless motor has no detent force to help. Continuous thrust has to cover the holding load on top of the acceleration duty, which drives the thermal calculation, and the axis needs a brake or counterbalance with defined behaviour on power loss and emergency stop. Vertical applications should be reviewed as a specific case.

Can an existing screw or belt axis be converted?

Sometimes, but rarely as a drop-in. The base needs a machined mounting datum for the track, the guide has to be re-evaluated now that the motor contributes no normal load, a linear scale has to be added, and the drive must support linear motor commutation. Send the existing drawings and we can advise whether conversion or a new axis is the better route.

Talk to Us Before the Base Is Machined

On a direct drive axis the mounting structure is part of the motor specification, not something settled afterwards. The air gap budget has to be agreed against the surfaces you can actually machine.

Send the duty cycle and the mechanical context above and we will work back to coil length, winding, track configuration, scale and drive together.

[Request a Drawing] · [Request Technical Consultation]·[Video Gallery]

Prev:

Next:

Inquiry

    PersonalBusinessDistributor