Manufacturer of Linear Modules,Linear Motors,Electric Cylinders,Truss System!

Truss & Robot Track Systems/Linear Motion/

  • Product Details

Truss Manipulator Selection : Reading the TM-TS Model Code and Matching structure to load, reach and accuracy

Author: DeMing, Engineering Director | Published:11th,Sept 2026| Category: Truss & Robot Track Systems 

Truss manipulator selection is quicker when it starts from the model code rather than from a picture. A TM-TS code records every decision that fixes a truss’s geometry and rating. Once each field is justified, the specification is essentially complete.

This guide reads the code field by field and lays the eleven catalogue configurations side by side on the same published parameters. It then works through what separates them and how each line of the selection sheet feeds the design. Applications and project references for the same range are on the TallMan Robotics truss manipulator page.

Truss-Based Manipulator Truss-based manipulators

How to read a TM-TS truss manipulator code

The naming guide’s worked example is TM-TS-CM-H2M-2X5M15+2Y2.5M10+2Z1M08-RA05-50KG.

Field In the example What it specifies
Series TM-TS Truss system
Environment CM CM open · CR fully enclosed in sheet metal · CF fully enclosed under bellows covers
Column height H2M Column height, 2 m
X axis count 2 2 = two X axes · a single axis is written without a number · X+X = two different X axes
X axis X5M15 Total length 5 m, speed 1.5 m/s
Y axis count 2 Same convention as the X axis
Y axis Y2.5M10 Total length 2.5 m, speed 1.0 m/s · no Y group means a two-axis truss
Z axis count 2 Same convention as the X axis
Z axis Z1M08 Total length 1 m, speed 0.8 m/s
Rotation axis RA05 R = first rotation axis, A = second · 05 = 0.5 r/s · omitted when there is none
End load 50KG Maximum load at the end of the Z axis

Two conventions catch people out. The digits after M give a speed in tenths of a metre per second, not a length. M08 is therefore 0.8 m/s and M35 is 3.5 m/s. The selection sheet, on the other hand, heads its speed rows in mm/s, so convert a value before copying it from a code into the sheet.

Truss Manipulator Manufacturers Truss Manipulator Solution Truss Manipulator Structure

The eleven catalogue trusses, decoded

Every truss in the catalogue is published with an example code. Decoded side by side, they show how column height, axis count and speed shift with the job. These are example builds rather than limits, and a quoted system gets a code written for it.

No. Configuration Column X axis Y axis Z axis End load
01 Moving-beam welding gantry 2 m 2 × 10 m, 1.5 m/s 5 m, 1.0 m/s 3 m, 0.5 m/s 500 kg
02 Gantry truss 2.5 m 2 × 4 m, 2.0 m/s 3 m, 2.0 m/s 2 m, 1.0 m/s 200 kg
03 Tyre sorting truss 3 m 2 × 20 m, 3.5 m/s [confirm] 11 m, 3.5 m/s [confirm] 2 m, 2.0 m/s 200 kg
04 Hard rail roller truss 2.8 m 2 × 4 m, 1.5 m/s 2 m, 1.5 m/s 2 m, 1.0 m/s 100 kg
05 Heavy-duty double Y beam 2.5 m 2 × 10 m, 1.0 m/s 2 × 5 m, 1.0 m/s 2 × 1 m, 0.3 m/s 500 kg
06 Aluminium beam gantry 2 m 2 × 4 m, 1.5 m/s 3 m, 1.5 m/s 2 m, 1.0 m/s 100 kg
07 Gantry two-axis truss 2 m 5 m, 1.5 m/s — 1.5 m, 1.0 m/s 20 kg
08 Overhung-column two-axis 2.5 m 5 m, 1.5 m/s — 2 m, 1.0 m/s 20 kg
09 Ram-type aluminium beam 2.2 m 3 m, 1.5 m/s 1 m, 1.0 m/s 1 m, 1.0 m/s 100 kg
10 Cantilever three-axis 2 m 2 m, 1.5 m/s 1 m, 1.0 m/s 2 m, 1.0 m/s 50 kg
11 Steel beam + module 1.8 m 3 m, 1.0 m/s 0.5 m, 0.5 m/s 0.5 m, 0.5 m/s 10 kg
Modular Truss Manipulator Efficient Truss Manipulator Automatic Truss Manipulator

Envelope and published performance for truss manipulator selection

The series sits inside one basic specification.

Basic specification Value
Maximum X axis length 200 m
Maximum Y axis length / gantry span 25 m
Maximum Z axis length 5 m
Maximum load 5,000 kg
Maximum speed 3 m/s
Repeat positioning accuracy grades ultra-high ±0.01 mm · high ±0.02 mm · medium ±0.05 mm · general ±0.1 mm

Within that envelope, each configuration carries its own published ranges.

No. Configuration Load Length Cantilever Repeatability Speed
01 Moving-beam welding gantry 0–5,000 kg 0–100 m 0–25 m ±0.1 mm 0–1 m/s
02 Gantry truss 0–500 kg 0–100 m 0–10 m ±0.03 mm 0–3 m/s
03 Tyre sorting truss 0–500 kg 0–100 m 0–15 m ±0.2 mm 0–3.5 m/s [confirm]
04 Hard rail roller truss 0–500 kg 0–100 m 0–15 m ±0.1 mm 0–1.5 m/s
05 Heavy-duty double Y beam 0–3,500 kg 0–100 m 0–12 m ±0.05 mm 0–1.5 m/s
06 Aluminium beam gantry 0–500 kg 0–100 m 0–4 m ±0.05 mm 0–1.5 m/s
07 Gantry two-axis truss 0–100 kg 0–100 m 0–4 m ±0.1 mm 0–1.5 m/s
08 Overhung-column two-axis 0–200 kg 0–100 m 0–1 m ±0.05 mm 0–1.5 m/s
09 Ram-type aluminium beam 0–150 kg 0–100 m 0–1 m ±0.05 mm 0–1.5 m/s
10 Cantilever three-axis 0–150 kg 0–100 m 0–1 m ±0.05 mm 0–1.5 m/s
11 Steel beam + module 0–100 kg 0–100 m 0–1 m ±0.02 mm 0–1.5 m/s

Truss manipulator selection : what separates the configurations

Reach follows the support geometry

The cantilever column falls into three groups, and the grouping follows how the axes are supported rather than how heavy the machine is. The five double-X gantries (01 to 05) publish 10 to 25 m. The two aluminium-beam gantries (06 and 07) publish 4 m. The four single-beam trusses on columns (08 to 11) publish 1 m. The welding gantry’s 25 m matches the 25 m gantry span limit in the basic specification.

That makes reach the first filter in truss manipulator selection. If the handling point sits beyond the reach a single-beam truss publishes, those four configurations drop out before load or accuracy come into it.

Heavy loads run slowly, and the arithmetic says why

The heaviest truss in the range is also the slowest. The welding gantry carries up to 5,000 kg at up to 1 m/s, while the fastest gantries carry 500 kg. Kinetic energy explains the pattern, E = ½mv², because the drive puts that energy in on every start and takes it out on every stop. A 5,000 kg moving mass at 1 m/s stores 2.5 kJ. At 3 m/s the same mass would store 22.5 kJ, nine times as much. The motors, reducers and structure would have to absorb all of it within the braking distance.

The double Y beam in configuration 05 is the other route to a higher load. Two parallel Y beams lift the carried load to 3,500 kg while the truss still runs at up to 1.5 m/s.

Repeatability is a grade, not a by-product of size

The tightest figure in the table, ±0.02 mm, belongs to one of the smallest machines: the steel beam truss whose Y and Z axes are linear modules. The general gantry truss follows at ±0.03 mm. The double-Y gantry, the aluminium beam gantry and three of the single-beam trusses sit at ±0.05 mm. The welding gantry, the roller truss and the two-axis gantry are at ±0.1 mm, and the tyre sorting truss is published at ±0.2 mm.

The catalogue does not tie a grade to a particular guide or drive specification. In truss manipulator selection the grade is therefore confirmed at quotation, against the tolerance that the part and the fixture actually need at the place-down point.

Steel, aluminium profile, or steel with linear modules

The catalogue describes three ways of building the beams. The welding gantry uses a welded steel body for stiffness and strength under heavy load. The aluminium-beam configurations (06, 07 and 09) are built for shorter delivery. Their loads are published up to 500 kg on the gantry and 100 to 150 kg on the smaller machines. Two configurations mix the materials. The cantilever three-axis truss uses steel beams for X and Y with an aluminium Z axis. The steel beam truss pairs a steel X beam with Y and Z axes built from linear modules. For the module side of that pairing, screw linear module selection covers lead, preload and critical speed.

Rollers on hard rails where the track gets dirty

Configuration 04 runs on rollers over hard rails. The catalogue gives the reason directly: sprayed adhesive landing on the track would wear the guide rail, and the roller arrangement avoids that wear. For spraying lines and bagged cement handling, it is the configuration to look at first, rated to 500 kg at ±0.1 mm.

Truss Manipulator Selection Truss Manipulator Selection Truss Manipulator Selection

Enclosure codes on TechMan Truss Manipulator Selection

The environment field takes one of three values. CM is open. CR encloses the axes fully in sheet metal. CF encloses them under bellows covers, which fold with the axis travel and keep dust and spray off the guideway. Engineering chooses between them from the usage-environment boxes on the selection sheet: dust, debris, spray, spraying, outdoor, conventional and salt-spray corrosion. The engineering of bellows covers on linear axes is covered on the IP65 bellows cover linear module page.

Filling in the Truss Manipulator Selection sheet

The selection sheet is the other half of truss manipulator selection. Each block below changes something specific in the design.

Building height and column height

The column height in the code is designed against the factory building height entered on the sheet. Everything above the floor has to clear the roof structure, the lighting and any overhead crane. That includes the column, the beam on top of it and the Z axis at the top of its stroke.

Up to four Y axes and four Z axes

The sheet gives four columns each for Y and Z axes, with total length, maximum speed and load entered for every axis. One truss can therefore carry several Y beams or several Z axes under the same X axes, as the double-Y truss does with two of each. Load goes in per axis because each axis is sized for what it carries. The end load in the code is the rating at the tool.

Gripper, rotation axes and the part

A block marked “fill in when needed” defines the end of the arm. It records whether an R or A rotation axis is required, also sets the gripping method: pneumatic gripper, servo gripper, electromagnetic suction, mechanical hook or vacuum suction cup.  The form then asks for the part’s name, form, dimensions and weight, with drawings or photos. Part weight plus gripper weight has to sit inside the end load in the code.

Supply scope, sensors and customer-supplied parts

Supply is the mechanical structure only, the structure with electrical accessories, or the structure with an electrical program. The reducer, motor, guide rail, rack, sensor, drag chain, touch screen and PLC each have a brand line and a customer-supply box. The sensor field also asks for NPN or PNP, which has to match the input type of the controller reading those sensors.

Site conditions

The last lines cover floor level, crane use on site and installation scope. Engineering uses them to plan transport sections and the erection sequence.

Measuring the finished structure

granite surface plate and dial indicator inspection for truss manipulator beams

Granite surface plate used as the measuring datum.

Flatness and straightness on structural parts are read with dial indicators against granite surface plates. A height gauge and a coordinate measuring machine cover part geometry, and positioning is verified with a laser interferometer. The inspection sequence is documented on the linear module quality control page.

FAQ about Truss Manipulator Selection

What does “2X10M15” mean in a truss manipulator code?

Two X axes, each 10 m in total length, running at up to 1.5 m/s. The leading digit counts the axes and the number after X is the length in metres. The two digits after M give the speed in tenths of a metre per second.

Can one truss carry two Z axes?

Yes. The code allows a count in front of each axis group, and the selection sheet has four Z columns. Configuration 05 carries two Y beams and two Z axes, each Z axis with its own stroke, speed and load.

Which repeatability grade should be specified?

Start from the tolerance the part and the fixture need where the part is placed. The four published grades run from ±0.01 mm to ±0.1 mm. State the tolerance on the selection sheet and the grade is confirmed at quotation.