Shaft Linear Motor | GM Series Ironless Rod Motor
Author: DeMing, Engineering Director | Published: 9th,Sept 2016 | Category: Linear Motor Systems
A shaft linear motor rolls the magnet track into a sealed round tube and wraps the coil around it. The forcer, referred to as the rotor in some supplier catalogues, slides along that tube with clearance the whole way round, touching nothing, and its thrust acts along the shaft axis straight into whatever it is bolted to.
The round geometry is the whole argument. In a flat or U-channel motor the coil faces the magnets across a plane, and the gap on each side is a tolerance to be budgeted and then defended through the life of the machine. Wrap the coil around the magnets instead and the radial pull on one side is answered by the pull on the other. Nothing tries to close the gap. Every model in the GM range is listed at zero magnetic attraction, and the winding sits in field around its full circumference rather than only on its active faces.
The feature note issued with the catalogue describes the GM construction as an eccentric arrangement of forcer and shaft, credited with keeping the assembly light, simple to fit and rigid once mounted. TechMan Robotics supplies the series as separate forcers and magnetic shafts for customer-designed axes, and as coded combinations, including several forcers sharing one shaft.

Image 1 . GM series shaft linear motor forcers and magnetic shafts
Inside the Shaft and the Forcer
The stator is a tube, stainless steel or epoxy covered, filled with disk magnets stacked pole to pole. Like poles meet at every joint, so the flux cannot run along the axis and is driven out radially through the wall of the shaft, reversing at each boundary. The spacing between like poles is the pole pitch, which the drive needs at commutation setup: 60 mm on GM16, 72 mm on GM20, 90 mm on GM25 and 120 mm on GM35.
The forcer is a three-phase winding wound as a cylinder around that tube and encapsulated in a rectangular body with a flat mounting face. There is no iron in it. Current through the winding meets the radial field and the product is force along the axis, with no slotting to produce a force that repeats with position and nothing in the motor that wears.

Image 2. Working principle along the axis of travel. Disk magnets stacked pole to pole drive the flux radially out of the shaft, and the coil forcer surrounds the shaft with clearance all round.
What Is in the Assembly of a Shaft Linear Motor
Magnetic shaft (stator). The sealed tube of stacked disk magnets. Ordered by frame size and length, from 100 mm up to the maximum for the frame, with the covering stated as S for stainless steel or E for epoxy.
Forcer. The moving part: the encapsulated three-phase winding in a body with a flat mounting face and four tapped holes. Mass runs from 0.1 kg on the smallest GM16 to 2.4 kg on the longest GM35.
Hall sensor option. NH is supplied without; H9D adds Hall sensors with the cable terminated in a DB9 plug. This gives the drive a commutation reference at power-up and is not position feedback.
Cable. The forcer code carries the cable length, 0.3 m being the standard entry. State the length the carriage run actually needs — a cable spliced at the machine is a failure point on a moving axis.
Magnetic ring. FB or NFB in the forcer code. The catalogue names the option without describing it; see the open items.
No Magnetic Pull, and Why the Round Shape Matters
Magnetic attraction is listed as 0 kN for all sixteen models. On any ironless motor that means the guide carries the payload and the process forces and nothing else, so rail size follows the real moment loads and bearing life follows the real duty cycle. The round geometry adds something the flat topologies cannot offer: pull on one side of the winding is cancelled by pull on the opposite side, so a forcer sitting slightly off centre is not drawn further off centre. Misalignment spends mechanical clearance and only mechanical clearance.
That changes the nature of the alignment work. A U-channel axis has a flat clearance budgeted per side, and base flatness, rail straightness and bracket deflection all draw on the same account. Here the requirement is that the shaft stays straight and the forcer bore stays concentric to it over the stroke, which comes down to how the guide runs relative to the shaft and how square the bracket is that joins the carriage to the forcer.
The forcer does not float. It is bolted to a carriage on its own guide and contributes no normal load to it. If the same pull-free behaviour is wanted in a flat envelope, the U-shaped ironless range is the sibling product; where force density matters more than smoothness and an attraction load is acceptable, the iron core flat motor range is the better place to start.
The GM Order Code, Layer by Layer
Every GM part number states what the part is. GM35-160-105 is a 35 mm shaft, a 160 mm forcer body and 105 N continuous thrust. GM16-50-05 is a 50 mm forcer at 5 N, GM25-210-75 a 210 mm forcer at 75 N. Thrust scales with body length because a longer winding covers more of the magnet stack at any instant.
Three code layers sit on that, one for each way the parts can be ordered:
GM16-L200-S magnetic shaft: frame, length, covering
GM16-50-05-NH-0.3-S-NFB forcer: frame, body length, thrust, Hall, cable, winding, ring
GM16-C4-50-05-NH-0.3-L200 combination: forcer quantity and shaft length included
S and E are the shaft coverings, stainless steel and epoxy. NH and H9D are the Hall options. S and P in the forcer code are the series and parallel winding connections. NFB and FB are the magnetic ring options. In the combination code the quantity field sits after the frame size and the shaft length is carried at the end, so a single string describes a complete shaft together with the forcers that run on it.

Image 3. Assembled GM shaft linear motors in three frame sizes, showing the power cable and the separate Hall sensor lead on the H9D option.
GM Range Specifications of Shaft Linear Motor
The continuous columns describe a self-cooled motor with the coil at 100 °C and 25 °C air around it. Peak runs roughly four times continuous throughout the range.
|
Model |
Body length (mm) | Cont. thrust (N) | Peak thrust (N) | Cont. current (Arms) | Force constant (N/Arms) |
Forcer mass (kg) |
|
GM16-50-05 |
50 | 5 | 19 | 0.65 | 7.7 | 0.1 |
|
GM16-80-10 |
80 | 10 | 40 | 0.62 | 16 | 0.15 |
|
GM16-110-15 |
110 | 15 | 60 | 0.62 | 24 |
0.2 |
| GM16-140-20 | 140 | 20 | 80 | 0.62 | 33 |
0.3 |
| GM20-60-09 | 60 | 9 | 36 | 0.65 | 13.8 |
0.1 |
|
GM20-94-18 |
94 | 18 | 70 | 0.59 | 31 | 0.3 |
|
GM20-130-28 |
130 | 28 | 110 | 0.59 | 47 | 0.5 |
|
GM20-166-38 |
166 | 38 | 150 | 0.59 | 64 | 0.7 |
|
GM25-75-19 |
75 | 19 | 79 | 1.3 | 14 | 0.2 |
|
GM25-120-40 |
120 | 40 | 160 | 1.28 | 31 | 0.8 |
|
GM25-165-60 |
165 | 60 | 240 | 1.28 | 47 |
1.1 |
| GM25-210-75 | 210 | 75 | 300 | 1.28 | 59 |
1.5 |
| GM35-100-52 | 100 | 52 | 175 | 1.5 | 35 |
0.4 |
| GM35-160-105 | 160 | 105 | 415 | 1.5 | 69 |
1.3 |
| GM35-220-150 | 220 | 150 | 590 | 1.5 | 99 |
1.9 |
| GM35-280-190 (parallel) | 280 | 190 | 760 | 2.7 | 70 |
2.4 |
Electrical and thermal data for the same sixteen models:
|
Model |
Peak current (Arms) | Resistance (Ω) | Inductance (mH) | Back-EMF Ke (Vpeak/(m/s)) | Km (N/√W) |
Kthn (W/°C) |
|
GM16-50-05 |
2.5 | 10.5 | 4.1 | 2.4 | 2.4 |
0.22 |
| GM16-80-10 | 2.5 | 21 | 8.2 | 5.4 | 3.5 |
0.4 |
|
GM16-110-15 |
2.5 | 33 | 12 | 8.1 | 4.2 | 0.51 |
|
GM16-140-20 |
2.5 | 43 | 16 | 11 | 4.9 | 0.47 |
|
GM20-60-09 |
2.5 | 14.3 | 9.6 | 5 | 3.7 | 0.24 |
|
GM20-94-18 |
2.4 | 28.7 | 19.3 | 10 | 5.7 | 0.4 |
|
GM20-130-28 |
2.4 | 43 | 29 | 16 | 7.2 | 0.5 |
|
GM20-166-38 |
2.4 | 56 | 39 | 21 | 8.6 | 0.65 |
|
GM25-75-19 |
5.4 | 3.9 | 5 | 4 | 7.4 | 0.26 |
| GM25-120-40 | 5.1 | 7.8 | 10 | 10 | 11.2 |
0.43 |
| GM25-165-60 | 5.1 | 12 | 15 | 16 | 13.5 |
0.66 |
| GM25-210-75 | 5.1 | 15 | 19 | 20 | 15.1 |
0.82 |
| GM35-100-52 | 6 | 7 | 10.8 | 4 (see open items) | 13.1 |
0.53 |
| GM35-160-105 | 5.4 | 13.8 | 21.8 | 23 | 18.8 |
1.04 |
| GM35-220-150 | 5.4 | 20.2 | 33 | 33 | 22.2 |
1.3 |
| GM35-280-190 | 10.5 | 6.9 | 10.9 | 23 | 26.8 |
1.44 |
Frame-level mechanical and magnetic data:
| Frame | Shaft dia. S (mm) | Body width W (mm) | Mounting W1 (mm) | Mounting holes M | Pole pitch (mm) |
Shaft length range (mm) |
|
GM16 |
16 ±0.2 | 30 ±0.3 | 16 ±0.2 | 4-M3, 5 deep | 60 | 100 – 1725 |
|
GM20 |
20 ±0.2 | 40 ±0.3 | 20 ±0.2 | 4-M4, 6 deep | 72 | 100 – 2680 |
| GM25 | 25 ±0.2 | 50 ±0.3 | 25 ±0.2 | 4-M6, 8 deep | 90 |
100 – 2500 |
| GM35 | 35 ±0.2 | 60 ±0.3 | 30 ±0.2 | 4-M8, 9 deep | 120 |
100 – 2400 |
Electrical time constant groups by frame rather than by model: about 0.37 ms on GM16, 0.67 ms on GM20, 1.27 ms on GM25 and 1.58 ms on GM35. Check it against what the drive’s current loop can actually follow. Km, the motor constant, is what to compare between frames when heat rather than peak force is the binding limit, and it climbs from 2.4 N/√W on the smallest GM16 to 26.8 N/√W on the largest GM35.
Insulation is class B. The bare motor is rated IP00, which describes the motor and not the machine: inside a closed cabinet it is not a limitation, and in an open, wet or dusty installation the sealing has to be designed around the axis. Bus voltage is capped at 330 Vdc. RoHS and CE are stated.
Several Forcers on One Shaft
The combination code carries a forcer quantity, and that is a capability rather than a packaging detail. The magnetic shaft is one continuous magnet stack, so any number of forcers can sit on it, each an independent axis with its own drive, feedback and commutation. Multi-carriage transport, two heads working the same line, a load station and an unload station on one rail — none of them needs a second motor track.
Two limits come with it. Forcers cannot pass one another, so the stroke each one gets is carved out of the same shaft, and the closest they can approach is the body length plus bracket and cable management, not the body alone. In practice the cable routing for the moving forcers settles the layout before the motor does.
Supporting the Shaft
This is the constraint that shapes the axis. The forcer travels the full length of the shaft, so there is nowhere to put an intermediate support: the shaft is held at its ends and the span is whatever the stroke demands. That is why the catalogue stops where it does, at 1725 mm on GM16, 2680 mm on GM20, 2500 mm on GM25 and 2400 mm on GM35.
Across that span the shaft carries its own weight, and the resulting sag has to stay comfortably inside the annular clearance between shaft and bore. Orientation decides how much of a problem that is — a vertical shaft does not deflect at all — and so does where the forcer sits when the axis is parked. The catalogue pairs each stator length band with an end bracket dimension:
| Frame | Stator length L (mm) |
Bracket length L1 (mm) |
|
GM16 |
100 – 350 | ≤ 25 |
|
GM16 |
351 – 800 | ≤ 40 |
|
GM16 |
801 – 1725 | ≤ 60 |
|
GM20 |
100 – 300 | ≤ 25 |
|
GM20 |
301 – 700 | ≤ 40 |
|
GM20 |
701 – 2680 | ≤ 60 |
| GM25 | 100 – 700 |
≤ 50 |
| GM25 | 701 – 1500 |
≤ 70 |
| GM25 | 1501 – 2500 |
≤ 100 |
| GM35 | 100 – 750 |
≤ 50 |
| GM35 | 751 – 1500 |
≤ 70 |
| GM35 | 1501 – 2400 |
≤ 100 |
Usable stroke is shaft length less forcer body length, less overtravel at each end for bracket, cable anchor and limit switches, and on a shared shaft less the space the other forcers take. Confirm it against the mechanical layout rather than reading it off the shaft length.
Winding Options and the Speed Ceiling of our Shaft Linear Motor
Fifteen of the sixteen models are tabulated series-wound; only GM35-280-190 is shown parallel. Set it beside GM35-220-150 and the effect is visible in every column: force constant falls from 99 to 70 N/Arms, continuous current climbs from 1.5 to 2.7 Arms, phase resistance drops from 20.2 to 6.9 ohms and inductance from 33 to 10.9 mH.
Speed is where it pays. Back-EMF constant falls with force constant, and the voltage-limited ceiling is roughly bus voltage over Ke. GM35-220-150 at Ke 33 Vpeak/(m/s) reaches about 10 m/s on a 330 Vdc bus; the parallel GM35-280-190 at Ke 23 reaches about 14 m/s. On the small frames the ceiling is so far away that it stops being the question at all, and what limits the axis is shaft dynamics, the guide and how fast the scale can be read. Specify the winding you want rather than accepting the one the table happens to show.
What Sets the Continuous Rating in the Shaft Linear Motor
An ironless winding has nowhere to send heat except its own body and the face it is bolted to, which is why the continuous columns sit so far below peak and why duty cycle deserves arithmetic rather than optimism.
Two catalogue figures make that arithmetic possible: continuous thermal power P_cn and the dissipation constant K_thn. One divided by the other is the temperature rise the rating assumes. Run it across the range and it holds — 16.5 W against 0.22 W/°C on GM16-50-05 gives 75 K, 61.5 W against 0.82 W/°C on GM25-210-75 gives 75 K, 112.3 W against 1.44 W/°C on GM35-280-190 gives 78 K. All three land on the 100 °C coil limit from 25 °C air, which is where the continuous numbers came from to begin with.
Two things follow. Work the axis well under its rated RMS current and it runs cooler than the table suggests. Put it in a warm cabinet and the headroom drops by the ambient difference, one degree for one degree. There is no water-cooled variant in the GM range, so the mounting face is the only lever left: bolting the forcer to an aluminium carriage and bolting it to a thin plastic adapter are not the same motor thermally.
Feedback and Hall Sensors
A direct drive axis has no transmission to infer position from, and the GM forcer carries no scale of its own, so the axis needs a linear encoder. The H9D option is not a substitute: Hall sensors tell the drive where the poles are at power-up, which is a commutation question, not a positioning one.
Choosing between magnetic and optical, working out where read speed starts to cap a fast axis, and deciding whether absolute startup earns its cost are covered on the linear motor feedback system page.
Matching a Servo Drive
The current figures look undemanding — 0.59 to 2.7 Arms continuous — but peak runs about four times higher, reaching 10.5 Arms on the parallel GM35. Size the drive on the peak column. A drive chosen against the continuous figure will clip at exactly the moment the profile calls for acceleration. Bus voltage is capped at 330 Vdc.
Which drive families commutate a linear motor, how peak current maps onto drive frames, and what the feedback interface rules in or out are set out on the linear motor drive page. Forcer and shaft can be supplied as components to suit a drive already in the machine, or the axis specified as one package with feedback, guide and drive.
Jobs a Shaft Motor Is Right For
What the round envelope and the balanced winding actually buy is easier to see by the job than by the industry:
Tight or round envelopes. A shaft and a bore occupy less cross-section than a channel and a flat forcer, and the motor can run in line with a round guide or inside a tube. Where there is no room for a flat magnet track, this is often the only direct drive that fits at all.
Short, fast, repetitive moves. From 0.1 kg on GM16 the moving part is barely there, so the axis accelerates hard and stops ringing quickly. Bonding heads, probe and test positioning, small-part handling and dispensing heads sit here, where the clock is run by settling rather than by top speed.
Constant velocity through a pass. Nothing in the coil is slotted, so no force repeats with position for the loop to chase and velocity stays flat through a scan, a weld or a dispense line.
Several carriages on one axis. Forcers sharing a shaft turn a single motor track into a small transport system, which changes what a transfer or buffering station costs to build.
Where it is the wrong choice: strokes beyond the catalogue shaft lengths, because there is nowhere to add an intermediate support; pressing, machining or anything that wants force density rather than smoothness; heavy vertical holding, since nothing detents the forcer in place; and unenclosed wet or dusty work. If the duty is ordinary point-to-point positioning and a scale plus a linear-motor-capable drive is more than the job warrants, a screw-driven module does it for less.
What We Need to Quote for a Shaft Linear Motor
A thrust figure on its own does not choose a model. Four things do:
The cycle. Mass on the forcer and where its centre sits, stroke, distance and time per move, idle time between moves, top speed and acceleration, moves per hour, hours per day.
The machine. Orientation, the envelope the shaft and forcer have to live in, which guide carries the carriage, how the bracket joins carriage to forcer, and any process force pushing back.
The target. How repeatable, how accurate, how long the axis may take to stop moving, and which of smoothness or cycle time the machine is actually judged on.
The surroundings. Ambient temperature, enclosure and contamination, an existing drive if this is a retrofit, the controller interface, and how many forcers share the shaft.
From that we can size RMS thrust and coil temperature against the real cycle and come back with forcer length, winding, shaft length and covering, feedback and drive capacity as one specification.
Send us a duty cycle and we will size a shaft linear motor axis around it. Want to compare with electric cylinder, you can go to this page.
FAQ about a Shaft Linear Motor
How long can the shaft be?
The catalogue tops out at 1725 mm on GM16, 2680 mm on GM20, 2500 mm on GM25 and 2400 mm on GM35. The limit is structural, not magnetic: the forcer has to travel the whole length, so the shaft is supported only at its ends and the sag over that span has to stay inside the clearance between shaft and bore. Longer travel calls for a different topology, not a longer shaft.
Can several forcers run on one shaft?
Yes, and the order code carries the quantity. Each forcer needs its own drive, feedback and commutation, and since they cannot pass one another, allocate stroke and cable routing before the stations are laid out.
Does the coil touch the shaft?
No. The bore surrounds the shaft with clearance all round and nothing wears. Radial pull cancels around the circumference, so a small eccentricity does not drag the coil onto the shaft the way an off-centre iron-core forcer is drawn toward its track.
Do the Hall sensors replace a linear scale?
No. H9D gives the drive a commutation reference at power-up. Closed-loop positioning still needs a linear scale chosen for the resolution and speed the application requires.
Series or parallel winding?
Thrust per watt is the same either way. Parallel halves the force constant and doubles the current, which suits a drive with current to spare and a limited bus, and it lifts the speed ceiling because back-EMF halves along with force constant. Only GM35-280-190 is tabulated parallel, so ask for the option rather than reading it off the page.
Can the motor mount vertically?
Vertically the shaft does not sag, which helps. What does not help is that an ironless motor has no detent force, so the continuous rating has to hold the load as well as accelerate it and the thermal margin gets tighter rather than looser. Plan a brake or counterbalance and define what it does on power loss and emergency stop.
Is IP00 a problem?
Only where Shaft Linear Motor sits in the contamination. The rating describes the bare motor; in an enclosed machine it is not a constraint. In a wet or dusty environment the axis needs sealing designed around it, which is a machine-level decision rather than a motor option.