Technical Guide

How To Install a Linear Motor ?

Linear Motor Installation Guide: Flat, U shape and Shaft Types

Safety, Base design, Mounting tolerances and Assembly sequence for direct drive axes

Author: DeMing, Engineering Director | Published: 10th,Sept 2016 | Category: Technical Guide

A linear motor arrives as two loose parts with no bearing between them. Nothing holds the forcer at the right distance from the magnets except the structure you build, and nothing recovers a mounting error in software. That makes installation part of the motor specification rather than a step that follows it.

This guide covers the three motor architectures we supply — flat iron-core, U-channel ironless, and shaft rod — together with the handling and safety requirements common to all of them. Each type fails differently when installed badly, so the sections are separate, but the safety section applies to every one of them and comes first for a reason.

Safety: Read This Before Unpacking

A linear motor’s magnet assembly is not inert. It is dangerous to people and to the machine before any power is connected, and most injuries happen during handling rather than during operation.

New vector, ISO 7010

The four hazard classes this guide covers, shown with their ISO 7010 references

Magnetic field hazard

The field a linear motor produces can cause serious injury or death to people with implanted medical devices. Anyone wearing or carrying a pacemaker or a metal implant must not come within 120 cm of a linear motor. A person with an implant must maintain at least 100 cm from the machine.

This applies to unpowered motors in storage and to parts on a bench, not only to running axes. Mark the storage area and the assembly bay accordingly.

Attraction hazard during handling

Iron, steel and any other ferromagnetic object will be pulled into the motor. A large steel part approaching the magnet assembly can trap and crush a hand or an arm on impact.

  • Keep tools, fasteners and offcuts away from the magnet assembly during installation.
  • On shaft motors in particular, the magnet rod carries substantial attraction force. Plan how it will be held and set down before picking it up.
  • Never allow the magnet assembly to close on itself or on another magnet assembly uncontrolled.

Voltage hazard

If the coil surface is damaged, voltage can reach 600 V at the surface. That will destroy the motor and can damage adjacent components, and contact is potentially fatal.

The motor must be reliably earthed. This is not conditional on the drive or the machine design.

Storage

  • Store parts separately and do not stack them.
  • Packaging must be non-conductive.
  • The storage room must be free of magnetic influence, and motors must be kept at least 100 cm from other magnet assemblies.
  • Storage conditions: −25 °C to +65 °C, humidity ≤ 80 %, in a dust-free, clean environment with no corrosive gas, no abrasive fluid, no metal powder and no oil.

Before You Order

Two conversations belong before the purchase order rather than after delivery.

Environment.

Ingress protection depends on which product you are buying, and the two answers are far apart.

Component motors are IP00.

A forcer and magnet assembly bought as components — flat, U-channel or shaft — have no ingress protection at all. There is no seal, gasket or enclosure anywhere in either part. Dust, swarf, coolant and moisture reach the coil and the magnet faces directly unless the machine keeps them out. That makes protection a machine design task, and it has to be solved by whoever builds the axis:

  • Ferrous dust and swarf are the acute case. Non-magnetic dust settles; iron and steel particles are attracted to the magnet faces and accumulate there, and on a U-channel motor they accumulate inside the very gap the forcer runs through. A machining environment needs the motor enclosed, not merely shielded.
  • Coolant and moisture reach the coil directly. Where the process involves either, the axis needs a cover, a purge, or both, designed around the motor rather than added afterwards.
  • Orientation helps. An axis whose open faces point sideways or downward collects far less than one lying open to the ceiling of a machine that sheds debris.

Guide-rail type and embedded-guide-rail motors reach IP65.

These are complete linear motor axes with the guide integrated, and they can be supplied with a bellows cover over the travel, taking the assembly to IP65. If the application is contaminated and you want to keep direct drive, this is the route — the protection is engineered with the axis instead of being built around a bare motor afterwards.

So the environment question decides the product before it decides the specification. A dusty or wet application pushes you toward a guide-rail type motor with a cover, or away from direct drive altogether toward a covered mechanical axis — our IP65 bellows cover linear module page covers the screw and belt alternatives, and the helical rack and pinion linear module is available in a bellows-covered version too. All of them share the same cover geometry.

Duty.

Confirm the application requirement against the motor parameters with us before selection. A linear motor sized on peak thrust alone will not survive a continuous duty cycle, and the thermal calculation is the part that gets skipped.

Flat IronCore Linear Motors: The Attraction Force Sets the Structure

A flat iron-core motor pulls on its magnet plate continuously, with a normal force typically several times its rated thrust. That load never goes away and never varies with duty, and it is the dominant design case for the worktable and base.

Structural requirements in Linear Motor Installation

The worktable and base must be designed with sufficient strength and rigidity to resist the attraction load without deflecting. At the same time the moving assembly must not become heavy, or the mass penalty eats the acceleration the motor exists to provide. The resolution is material and geometry rather than section thickness: high-strength materials and multi-rib structures.

Two specific methods raise the rigidity where it matters:

Arched (crowned) structure. Pre-arch the moving structure so that the attraction load pulls it toward flat rather than away from it. The deflection under load is then designed for rather than resisted.

Raising rigidity against the attraction load: an arched structure, with the rail support points brought close to the coil

Raising rigidity against the attraction load: an arched structure, with the rail support points brought close to the coil

Bring the support points close to the coil. Position the guide rails and other support points as near to the motor coil as the layout permits. The attraction load acts at the coil, and every millimetre of overhang between the coil and its nearest support multiplies into deflection at the air gap.

Mounting tolerances in Linear Motor Installation

Feature

Tolerance (mm)

Dimensional gap, magnet plate to coil

0.7 ± 0.2

Flatness of the magnet plate and coil mounting surfaces

0.1
Parallelism of the magnet plate and coil mounting surfaces

0.1

Parallelism of the side datum faces of magnet plate and coil

0.1

Parallelism of the magnet plate and coil centrelines

0.2

Where each tolerance is measured: mounting datums, side datum faces and the magnet plate to coil centreline

Where each tolerance is measured: mounting datums, side datum faces and the magnet plate to coil centreline

Note the tolerance on the gap itself: ±0.2 mm on a 0.7 mm nominal. That is a wide band because it has to absorb the accumulated machining error of everything beneath it.

Design a shim into the coil side

Because the design gap is 0.7 mm and accumulated machining error will move it, design an adjustment shim on the coil side so the gap can be corrected at assembly rather than by re-machining. This is the single most useful thing you can put into a flat motor axis at drawing stage, and it costs nothing if it is planned and a great deal if it is not.

Assembly sequence in Linear Motor Installation

The order matters, because the coil cannot be introduced into a fully populated magnet track under control.

  1. With neither coil nor magnet plates fitted, set up the guide rails and worktable to their final accuracy. Then install only part of the magnet plates, leaving a reserved space with no magnets — this is where the coil will go in.
  2. Move the worktable into the magnet-free region and install the coil there. With no attraction acting, adjust the coil-to-magnet gap for uniformity along the length.
  3. Move the worktable to the far position and install the remaining magnet plates. Confirm every tolerance again, and the assembly is complete.

rails and worktable set to final accuracy with neither coil nor magnet plates fitted, then part of the magnet plates installed, leaving a reserved space for the coil

Step 1: rails and worktable set to final accuracy with neither coil nor magnet plates fitted, then part of the magnet plates installed, leaving a reserved space for the coil。

worktable moved into the magnet-free region, coil installed there, and the coil-to-magnet gap adjusted for uniformity with no attraction acting

Step 2: worktable moved into the magnet-free region, coil installed there, and the coil-to-magnet gap adjusted for uniformity with no attraction acting

worktable moved to the far position, remaining magnet plates installed, and every tolerance confirmed

Step 3: worktable moved to the far position, remaining magnet plates installed, and every tolerance confirmed

Disassembly is the same sequence in reverse. Do not attempt to lift a coil straight out of a fully populated track.

U Shap Ironless Motors: Centreline and Cleanliness

A U-channel motor has no attraction load to design against, so the structural problem disappears and is replaced by a geometric one: the forcer has to stay clear of both magnet faces over the whole stroke, inside a gap of well under a millimetre.

Design considerations

Align the centrelines. The coil assembly must be installed with its centreline aligned to the magnet assembly’s centreline, so the clearance around the coil stays even.

Leave envelope clearance. Design around the motor’s maximum external dimensions, with enough clearance for the assembly to be fitted and adjusted.

Mounting surface tolerances:

Feature

Tolerance (mm)
Flatness of the magnet assembly mounting surface

0.01

Parallelism of the magnet assembly mounting surface to the guide

0.1

These are two different geometric characteristics and the tenfold difference between them is intended. Flatness is a form tolerance on the surface itself, controlling local waviness that would tilt the magnet assembly and close the gap at one point. Parallelism is an orientation tolerance relating that surface to the guide, and it is allowed to consume more because a uniform angular error is taken up along the length rather than concentrated. Quote both to the machine shop as written.

Where several magnet assemblies are joined end to end, the clearance between them must be set according to the actual motor requirement rather than a nominal figure.

Linear Motor Installation

The U-channel stack: permanent magnets on both stator rows, the motor coil between them, and the fixing plate beneath

Clean the mounting surfaces before use. Both the coil assembly (forcer) and the magnet assembly (stator) mounting faces need cleaning before installation. A particle trapped under a mounting face is a tilt, and a tilt is gap.

Fitting the forcer in Linear Motor Installation

The black part of the forcer is epoxy resin. It must be protected in service and must not be scratched. There is no metal skin over it.

Before installation, check and clean the stator: no foreign matter is permitted inside the U channel. A chip left in the channel becomes a contact event on the first stroke.

Checking the gap after assembly

Once installed, slide the coil assembly slowly through its travel by hand and check the clearance between forcer and stator along the way. If it is not even, reposition the coil assembly and check again. This is a hand operation and it is worth doing properly — it finds what a static measurement at one position will not.

Stator mounting arrangements in Linear Motor Installation

Linear Motor Installation

Three typical stator mounting arrangements, differing in how the fixing bolts and the fixed base engage the stator body

Three typical stator mounting configurations are available, differing in how the fixing bolts and the fixed base relate to the stator body. The choice depends on the access available in the machine and on whether the stator needs to be removable without disturbing the base. Confirm the arrangement on the drawing before the base is machined, since it changes the bolt pattern.

For the UMA range specifications and the air gap figures by frame size, see our U-shape ironless linear motor page.

Shaft Rod Linear Motors: Concentricity and Deflection

A shaft motor’s forcer surrounds its magnet rod, so the constraint is concentric rather than planar, and the failure mode is the rod sagging into the forcer bore over a long span.

Installation requirements in Linear Motor Installation

Concentricity. When installing the forcer and the magnet rod stator, the offset between the two cross-section centre points must be ≤ 0.2 mm, vertically and laterally alike. This is the figure the whole installation is built around.

The concentricity requirement: the offset between the forcer bore centre and the magnet rod centre must stay within 0.2 mm in both directions

The concentricity requirement: the offset between the forcer bore centre and the magnet rod centre must stay within 0.2 mm in both directions

  • Check the model before fitting. After unpacking, confirm the ordered model number and that the physical form is correct before beginning installation. A shaft motor is awkward to remove once the rod is secured.
  • Use a non-magnetic base. The stator base must be made from non-ferromagnetic material. A steel base will distort the field and will fight the installation.
  • Handle the rod with the attraction in mind. The magnet rod carries substantial magnetic force and will attract tools and nearby objects. Plan the lift and the set-down.

Linear Motor Installation

Bolt the magnet rod stator down at the designated positions. The stator base must be non-ferromagnetic, and the rod’s attraction force must be planned for during handling

Place the magnet rod stator into the fixed base and secure it with bolts at the designated positions.

Controlling deflection in Linear Motor Installation

Over any significant length the magnet rod deflects under its own weight, and the deflection consumes the annular clearance between rod and forcer bore. A dedicated linear motor support bracket carries the rod so that forcer and stator do not rub anywhere within the effective stroke, and so that the bending and accuracy meet the machine requirement.

Linear Motor Installation

The standard linear motor support block, which carries the rod so that forcer and stator do not rub within the effective stroke

When the rod length exceeds what a standard support arrangement can control, the support blocks need adjusting. Four approaches, in increasing order of intervention:

  • Increase the fixed length of the bracket in proportion to the rod length. The simplest change and the first to consider.
  • Change a single-sided single support to a single-sided double support. Where the clamping range is limited, this costs less and changes the design less than a full redesign.
  • Adjust the parallelism of the centre holes of the double bracket. This corrects deflection directly by re-aiming the support line.
  • Add precision shims inside the two sections of a conventional support seat and tighten down. The simplest of all, and often sufficient.

Linear Motor Installation

Methods 2 and 3: single-sided double support in place of a single support, and correction by adjusting the parallelism of the double bracket’s centre holes

Linear Motor Installation

Method 4 and the two base-level approaches: precision shims inside the support seat, and a support base with adjustable positioning screws

Two base-level approaches are also available: controlling deflection by adjusting the base itself, and using a support base with adjustable positioning screws, which gives the widest adjustment range and the easiest access for it.

For the GM shaft motor range and its dimensions, see our shaft linear motor page.

Operation of Linear Motor Installation

  • The product is a precision mechanical component widely applied in machinery. It should be operated by technical personnel with the relevant knowledge and experience.
  • Operate within the product’s specified operating norms.
  • Where the application, the motor installation arrangement or the operating environment has special requirements, confirm with us before commissioning. This is how installation accidents and unnecessary losses are avoided.
  • No hot plugging. Do not connect or disconnect any terminal on the equipment with power applied — it will damage the motor and the drive.
  • Separate signal from power. Do not route control signal cables and power cables (mains supply, motor power leads) through the same conduit, and do not bundle them together.
  • Do not touch moving parts while the motor is running.

Maintenance and Shutdown in Linear Motor Installation

Before any work on the machine. Before moving, rewiring, maintaining or inspecting the equipment, cut the power and wait at least 4 minutes before starting work. Residual voltage remains in the power leads for roughly 3 minutes after the supply is cut.

Power cycling. Frequent switching degrades the main circuit components. After cutting power, wait about 2 minutes before re-energising, and limit switching frequency to once per 2 minutes.

Lubrication. Lubricate the linear guides on a defined schedule. The motor itself has nothing to lubricate; the guide does, and on a direct drive axis it is the only wearing element in the system.

Pre-Power Checklist

Common to all three types. Run it before the drive is connected.

  • Model number confirmed against the order, and physical form correct.
  • Mounting surfaces cleaned; no foreign matter in the U channel or around the magnet faces.
  • All mounting tolerances measured and recorded, not assumed.
  • Gap checked along the full stroke by hand, not at a single position.
  • Motor earthed.
  • Signal and power cabling separated.
  • Cable carrier travel checked over the full stroke with no snagging.
  • For component motors, ingress protection provided by the machine, appropriate to the environment — the motor itself has none.
  • Personnel with implanted medical devices excluded from the working area.

FAQ about Linear Motor Installation

Why does the flat motor installation sequence leave part of the magnet track empty?

Because a coil cannot be brought into a populated track under control — the attraction takes over as it approaches. Installing the coil in a magnet-free region lets you set the gap with no force acting, then the remaining magnet plates are added afterwards. The same logic applies in reverse on disassembly.

The flat motor gap is 0.7 mm and the U-channel air gap is also quoted around 0.7 mm. Are they the same thing?

No. On a flat motor, 0.7 ± 0.2 mm is the distance from the coil face to the single magnet plate it faces. On a U-channel motor, the figure is the clearance between the forcer and the stator it runs inside, with magnet rows on both sides. They are different measurements on different geometries, and the tolerance philosophies differ too — the flat motor carries a ±0.2 band and a design shim, the U-channel does not.

Can we install a linear motor without a shim provision?

On a flat motor it is strongly discouraged. The design gap is 0.7 mm and the accumulated machining error of the base, rails, table and brackets will move it. Without a shim the only correction available is re-machining a mounted assembly.

How long can a shaft motor be before deflection becomes the governing problem?

It depends on rod diameter and support spacing rather than on length alone, which is why the guide gives four escalating adjustment methods rather than a length limit. Send the stroke and the mounting arrangement and we will confirm the support configuration.

What happens if the motor is not earthed?

Damage to the coil surface can expose up to 600 V. Without a reliable earth, that voltage is present on accessible metalwork. Earthing is a requirement, not a recommendation.

What IP rating does the motor have?

It depends on the product. Motors supplied as components — a forcer and a magnet assembly for flat, U-channel or shaft types — are IP00 with no seal or enclosure on either part, and any protection the application needs is designed into the machine around them. Guide-rail type and embedded-guide-rail motors are complete axes and can be supplied with a bellows cover to IP65.

The distinction catches people who have previously specified a sealed mechanical actuator and assume a comparable rating carries over to a bare motor. It does not. If the environment is contaminated, raise it at selection rather than at installation, because it changes which product you should be buying.

Send Us the Mounting Arrangement Early

On a direct drive axis the base, the guide and the motor are one specification. The tolerances in this guide have to be achievable on the surfaces you can actually machine, and that is a conversation worth having before the base drawing is released.

Send the stroke, the duty cycle, the mounting orientation and the structure the motor will sit on. Our linear module design page covers how custom axis projects run, and linear module quality control covers the mounting-surface verification methods referenced throughout this guide.