Linear Motor Feedback System | Optical and Magnetic Scales

Author: DeMing, Engineering Director | Published: 9th,Sept 2016 | Category: Linear Motor Systems

A linear motor axis is only as good as the scale reading it. There is no screw pitch or belt ratio to infer position from, so whatever the reading head reports is what the servo loop believes — and every error in the scale becomes an error in the machine.

The trap in specifying one is that the headline number is the wrong number. A scale offering 0.1 μm resolution sounds like the safe choice until the axis is built and refuses to run above 36 m/min, because that resolution and that speed limit are the same specification seen from two directions. This page works through the relationships that decide which scale actually fits, then lists what TechMan Robotics fits to its linear motor systems.

What the Scale Does That Nothing Else Can

On a screw-driven axis the rotary encoder on the motor gives usable position, since the screw lead converts revolutions into millimetres. A linear motor has no such conversion. The forcer is coupled to the load directly, so position has to be measured where the load actually is.

The loop is short: motion controller issues a target, servo drive commands current, the forcer moves, the reading head measures where it ended up, and the drive corrects. Nothing in that chain estimates. If the scale mounting shifts by 20 μm, the machine is 20 μm wrong and has no way to know.

There is a second job specific to linear motors. The drive has to know where the forcer sits relative to the magnet poles before it can commutate. On a rotary servo that relationship is fixed at the factory; on a linear motor it depends on where the mover happens to be, so it must be established at every power-up unless the feedback supplies it directly.

Resolution Is Not Accuracy in  Linear Motor Feedback System

These get used interchangeably in enquiries and they measure different things.

Resolution is the smallest increment the system can report — the granularity of the count. The FAGOR EXA absolute series resolves to 0.01 μm.

Accuracy is how close a reported position is to the true one. The same EXA series is graded at ±5 μm per metre. The incremental version is graded at ±10 μm per metre.

The gap between the two is a factor of several hundred, and it is not a defect. Resolution governs how finely the servo can be told to move and how repeatably it lands. Absolute accuracy over the full stroke is set by how the scale was graduated and, in service, by its thermal state.

That thermal term deserves the arithmetic. The steel band carries a thermal expansion coefficient of about 11 ppm/K. Over a one-metre scale, a single degree of temperature change moves the graduations by 11 μm — twice the entire ±5 μm/m grading budget. On a linear motor axis this is not hypothetical: an ironless coil is rated to 100 °C and sits within a few centimetres of the scale, and the magnet track and machine base are thermal paths between the two.

The practical consequence is that repeatability specifications hold far better than absolute accuracy specifications. If your process needs the axis to return to the same place, resolution and mounting stability carry it. If it needs the axis to reach a dimensionally correct place over a long stroke, the thermal design of the base has to be part of the specification.

Finer Resolution Costs Speed

This is the relationship most often missed, and the FAGOR incremental range shows it cleanly because the arithmetic closes exactly across every model.

The reading head produces a signal period as it passes the graduations. Its electronics have a maximum frequency. Multiply the two and you have the maximum speed:

v_max = signal period × maximum frequency

Model Resolution Signal period Max frequency

Max speed

TA + L2RTD 5 μm 20 μm 200 kHz 240 m/min
TA + L2RX 1 μm 4 μm 1 MHz 240 m/min
TA + L2RY 0.5 μm 2 μm 1 MHz 120 m/min
TA + L2RW 0.1 μm 0.4 μm 1.5 MHz 36 m/min
TA + L2RP up to 0.1 μm 20 μm 400 kHz 480 m/min

Read the L2RW row against the L2RP row. Both reach 0.1 μm. One caps the axis at 0.6 m/s, the other at 8 m/s. The difference is where the interpolation happens — L2RW subdivides in the reading head and pays for it in frequency headroom, while L2RP outputs a 1 Vpp analogue sine-cosine signal on a coarse 20 μm period and lets the servo drive do the subdividing.

For a linear motor this matters more than it would on a screw axis. A UMA-series ironless motor is capable of several metres per second, and specifying a digital high-resolution head can quietly cap the axis at a fraction of that. Check the scale’s speed limit against the motion profile before the resolution is chosen, and if the application needs both fine resolution and real speed, an analogue output with drive-side interpolation is the route — provided the drive supports it.

Magnetic or Optical: What the Data Sheets Say

The usual summary is that optical means accuracy and magnetic means ruggedness. That is roughly right, and one part of it is commonly stated backwards.

Paramters

Optical (FAGOR EXA)

Magnetic (SIKO mMSK200)

Reading head protection IP40 IP67, EN 60529
Working temperature 0 °C to 50 °C −10 °C to 70 °C
Storage temperature −20 °C to 70 °C −30 °C to 80 °C
Relative humidity 20 – 80% 100%, condensation permitted
Best resolution 0.01 μm 0.5 μm
Vibration 200 m/s², 55–2000 Hz, IEC 60068-2-6 —
Shock 1000 m/s², 11 ms, IEC 60068-2-27 —

The environmental split is real and wide. An IP40 head in a machine that gets washed down, or a 0–50 °C rating in an unconditioned workshop, is a specification failure waiting to happen.

The part that gets stated backwards is installation. Magnetic scales are described as easier to mount, and in the sense that matters most — tolerance of dust, oil and coolant in the gap — they are. But the gap itself is tighter, not looser. The SIKO LEC160 sensor works at a ride height of 0.1 to 0.8 mm, the mMSK200 at 1 mm or less, and the HL20K magnetic head at 0.5 ±0.1 mm. The RU2 optical head runs at 2.1 ±0.2 mm. The optical head is the one that tolerates a larger and less precisely held gap over the stroke.

So the two claims should be separated. Magnetic tolerates contamination in the gap. Optical tolerates variation in the gap. A long axis on a base you cannot machine flat may well favour the optical head, which is the opposite of the usual advice.

Alignment tolerances for the magnetic heads run to roughly ±0.5 mm lateral offset, ±1° parallelism and longitudinal tilt, and ±3° lateral tilt on scales carrying reference marks. These belong in the assembly procedure alongside the motor’s own air gap budget, not in a commissioning checklist afterwards.

The Motor’s Own Magnetic Field

UMA catalogue states that the HL20K magnetic scale is intended for applications without a strong magnetic field. A linear motor is a strong magnetic field. The magnet track is a continuous array of rare-earth magnets, and the scale runs parallel to it, often within a few centimetres.

This is not a reason to rule magnetic scales out — they are fitted on linear motor axes routinely. It is a reason to treat the scale-to-track separation, the routing of the magnetic band, and any steel in between as design decisions rather than whatever the layout left over. If the axis is being retrofitted or the envelope is tight, this is the first thing to check with our engineering team, because moving a scale after assembly usually means re-machining a mounting face.

Optical scales are indifferent to the motor’s field, which is one reason they appear on high-precision linear motor stages more often than the resolution figures alone would explain.

The same field is a safety matter during handling and storage. Magnet tracks should be kept clear of magnetically sensitive equipment, and personnel with implanted medical devices such as pacemakers should not handle or approach them.

Absolute or Incremental for Linear Motor Feedback System?

For a linear motor this decision is heavier than it is elsewhere, because it changes what happens every time the machine is switched on.

An incremental scale counts from wherever it starts. The axis has to move to find its reference before it knows where it is. On a linear motor there is usually a second startup movement as well — the drive has to locate the forcer relative to the magnet poles before it can commutate correctly. Panasonic’s A6L linear drive series, for example, handles axes both with and without a magnetic pole position signal, detecting the relationship automatically where it is not supplied.

An absolute scale reads continuous binary position data and knows where it is the instant it powers up. No homing move, no pole-finding move, and no recovery routine after a power interruption mid-cycle. On a machine where the mover sits inside a tool, under a dispensing head or between fixtures, an uncommanded startup movement is not merely inconvenient.

Stroke length can decide this on its own. The EXA absolute series covers 70 mm to 3020 mm, in 50 mm steps. The incremental version covers 70 mm to 16,020 mm on the same step. Past three metres of measuring length, absolute is not on the table in this series and the machine has to be designed around a homing sequence.

The reading head also has to speak the drive’s language. EXA absolute heads are supplied in variants for SSI, Mitsubishi full and half duplex, Panasonic, BiSS and Yaskawa protocols. The drive is chosen first; the head follows from it. Getting this backwards is the most common cause of a scale arriving that cannot be connected.

Scale Options for TechMan Linear Motor Systems

Four scale families are offered across the linear motor range, and which one goes on the axis is the customer’s decision. Two are fitted as standard and cover most machines. The imported optical and magnetic scales are there for the cases the standard options do not reach — an absolute output, a sealed head for washdown, or a measuring length beyond the standard range. Tell us the requirement and we will quote whichever fits; tell us the part number and we will fit that.

HL20K magnetic scale — standard, general machine environments

Resolution of 1 μm or 0.5 μm against a 2 mm magnetic pitch, with a reading distance of 0.5 ±0.1 mm, or 0.3 ±0.1 mm where a steel band is added. Speed reaches 8 m/s at 1 μm resolution, and the finest resolution offered is 0.1 μm. Intended for machines without a strong external magnetic field.

HL20K magnetic scale reading head for linear motor feedback system Image 1. HL20K magnetic reading head on scale band

 

RU2 optical scale — standard, high precision

Resolution of 1 μm, 0.5 μm or 0.1 μm against a 40 μm or 20 μm grating pitch, with a reading distance of 2.1 ±0.2 mm. Speed reaches 12 m/s at 1 μm resolution, and the finest resolution offered is 20 nm. Intended for clean, shaded conditions.

RU2 optical grating scale reading head for precision linear motor axis

Image 2. RU2 optical reading head on grating scale

FAGOR EXA series — absolute and incremental optical

Open steel-band scales in absolute and incremental form. The absolute version reads continuous binary data at 0.01 μm or 0.05 μm resolution to ±5 μm/m, up to 480 m/min, with reading head cable lengths from 30 m to 75 m depending on variant and a 5 V ±10% supply drawing 250 mA unloaded. Head protection is IP40 and mass runs 0.17 kg plus 0.025 kg per metre.

SIKO magnetic scales — sealed industrial

The mMSK200 reads the MB200 band to 0.5 μm at a distance of 1 mm or less, sealed to IP67 and rated from −10 °C to 70 °C with condensation permitted. The LEC160 sensor reads the MB160 band with repeat accuracy to ±1 μm and resolution to 0.1 μm on a line-driver output, at a ride height of 0.1 to 0.8 mm, with LED status indication at the head.

Matching the Scale to the Machine

Three worked cases, because the decision rarely turns on a single specification.

A wafer inspection stage, 300 mm stroke, scanning at 200 mm/s, clean room. Speed is trivial for any of these scales, so resolution and thermal stability govern. An optical scale at 0.1 μm or finer, absolute if the tool cannot tolerate a homing move at power-up, and a base design that keeps the motor’s dissipation away from the scale mounting. The motor is likely to be thermally limited before the scale is.

A packaging transfer axis, 800 mm stroke, 2.5 m/s, washdown nearby. Here the IP40 optical head is the wrong component regardless of its accuracy. A sealed magnetic scale at 0.5 μm suits the duty, and the axis needs the magnet track separation checked because the enclosure will be tight.

A 5 m gantry, positioning to a few tens of microns. Absolute is unavailable at this length in the EXA series, so the machine gets a homing sequence and an incremental scale. Thermal expansion over 5 m dominates everything else — a 1 °C shift moves the scale by roughly 55 μm — so the specification has to state the ambient the accuracy figure applies at, and long strokes usually mean the scale is fixed at one end and free at the other so that growth is predictable rather than restrained.

Before You Specify a Scale

The order of these decisions matters, because each one closes options for the next.

  1. Fix the drive first. Interface protocol, whether it can interpolate an analogue signal, and whether it accepts an absolute format determine which reading heads are available at all.
  2. Take the maximum speed from the motion profile, then check it against the scale’s speed limit at the resolution you want — not at the resolution on the datasheet cover.
  3. Decide absolute or incremental from the machine, not the budget. Ask what happens if power is lost mid-cycle and whether an uncommanded startup movement is acceptable.
  4. Take the environment from the worst case, including washdown, coolant mist, ambient swing and proximity to the magnet track.
  5. Take the measuring length from the stroke plus overtravel, and check it against the series’ available range and step size.
  6. Then choose resolution, which by this point is usually constrained to one or two options.

Send us the motion profile, the drive model, the stroke and the environment, and our engineering team will specify the scale, head and mounting arrangement alongside the motor rather than after it.

Contact TechMan Robotics for linear motor feedback system selection. How electric cylinder drive itself? 

FAQ about our Linear Motor Feedback System

My axis is slower than the motor’s rating. Could the scale be the cause?

Frequently, yes. Multiply the scale’s signal period by the reading head’s maximum frequency to get its speed ceiling. High-resolution digital heads reach that ceiling well below what a linear motor can deliver — one 0.1 μm head in the FAGOR incremental range tops out at 36 m/min. An analogue output interpolated in the drive gives resolution without the speed penalty.

Can a magnetic scale be used next to a linear motor’s magnet track?

Yes, and it commonly is, but the separation is a design decision rather than an afterthought. The magnetic scales in this range are specified for environments without a strong external field, and a permanent magnet track is exactly that. Confirm the layout before the mounting faces are machined.

Why is the accuracy figure so much coarser than the resolution figure?

They describe different things. Resolution is the smallest step the system reports; accuracy is how close the reported position is to the true one over the full length. A scale resolving 0.01 μm and graded at ±5 μm/m is behaving normally. Repeatability tracks resolution; absolute accuracy tracks the grading and the temperature.

How much does temperature actually affect the reading?

The steel band expands at roughly 11 ppm/K, so a one-metre scale moves about 11 μm per degree. Over a five-metre gantry that is around 55 μm per degree. On tight tolerances the ambient temperature the accuracy applies at has to be stated, and the scale’s mounting has to let it grow in a predictable direction.

Does an absolute scale remove the startup movement entirely?

It removes the homing move, and it can also remove the pole-finding move a linear motor drive would otherwise make to establish commutation. Whether both are removed depends on the drive and how the feedback is configured, so confirm it against the drive documentation for the specific pairing.

Can a scale be added to an axis that does not have one?

Mechanically it is often possible, but it needs a flat, stable mounting face parallel to the travel within the head’s tolerance, a bracket that holds the ride height over the full stroke, and a drive that accepts the feedback. On a linear motor axis the magnet track position also has to be checked against the proposed scale location. Send the drawings and we can assess it.