How we proceed with Linear Module Quality Control in manufacturing?
Author:DeMing, Engineering Director, TechMan Robotics | Published: 3 September 2016 | Category: Company Capability
Linear Module Quality Control: Measuring Against a Granite Datum
A linear axis can only be measured against something flatter than itself. That is why every inspection station in our workshop sits on a granite surface plate. Linear module quality control here starts with the reference surface, not with the module.
The reason is practical. A guide rail bolted to a wavy surface takes on the shape of that surface. Straightness measured on an imprecise bench therefore tells you about the bench. Granite gives us a datum stable enough that the number we record belongs to the module.
![]() |
![]() |
Laser interferometer positioning measurement during linear module quality control
The Four Stages of Linear Module Quality Control
Our inspection system is organised into four formal stages, and each one owns a different question.
| Stage | Scope | Question it answers |
| IQC — incoming inspection | Purchased rails, screws and bought-out parts | Did the material arrive within tolerance? |
| IPQC — in-process inspection | Machining and assembly stages, sampled | Is the process still producing to specification? |
| QC — full inspection | Every finished axis | Does this individual module meet its drawing? |
| QA — outgoing inspection | Despatch batches, sampled | Is what we are shipping consistent with what we released? |
Non-conforming incoming material does not simply pass or fail. It goes to a return note, or to a documented special-acceptance approval when engineering judges the deviation tolerable for that order. Either route leaves a record. Inspection sheets are filed against the order rather than discarded once the module ships. Paper records stay on file for one year, and the scanned copies are kept indefinitely, so linear module quality control remains traceable long after despatch.
The Error Chain Runs in One Direction
Errors in a linear axis accumulate in a fixed order. Each stage of linear module quality control exists to stop one of them reaching the next. Rail flatness affects mounted straightness. Mounted straightness affects travel parallelism. Travel parallelism affects positioning accuracy at the carriage. Catching a deviation late means stripping the assembly. Our inspection sequence therefore follows the same order the errors do.
| Sequence | Checks performed |
| Incoming | Rail flatness, rail preload class |
| Rail assembly | Straightness, travel parallelism, rail alignment adjustment |
| Drivetrain | Belt tension, shaft end runout, lubrication charge |
| Mechanical integrity | Fastener tightness, cover-to-carriage clearance, customer hole pattern |
| Running behaviour | Smoothness under simulated motor load, noise, vibration |
| Finished axis | Positioning accuracy and repeatability by laser interferometer |
| Multi-axis | Orthogonality, gantry span alignment |
| Functional | Load, ingress, thermal shock, linear motor speed |
| Despatch | Cleaning and final visual |
Linear Module Quality Control Starts at Incoming Inspection
Guide rails go to the height gauge station before they reach any assembly bench. We check flatness across the rail seating faces on granite, because careful mounting never corrects a rail that already sits outside tolerance.
Preload class receives the same attention within linear module quality control, and it deserves more explanation. Carriage preload stays invisible from the outside. Yet it decides both the stiffness of the axis and the friction it runs at. Two rails that look identical can carry different preload grades. Verifying the grade on arrival keeps a mismatched pair off the same module. Such a pair shares load unevenly, and no later adjustment fixes it.
Incoming guide rail flatness inspection Guide rail preload class inspection Guide rail preload class inspection
Rail Assembly: Where Linear Module Quality Control Gets Decided
During assembly we clamp the rail to a granite reference of matching length, then adjust it with dial gauges while torquing it down.
Two measurements happen here, and the distinction matters. Straightness describes the rail as installed. Travel parallelism describes what the carriage does as it moves. That is the number a machine builder cares about, since payload follows the carriage rather than the rail. A rail can measure straight and still produce a parallelism error. The second rail only has to sit at a slightly different height along the run.
Straightness measurement on granite Travel parallelism measurement Rail alignment adjustment during assembly
Drivetrain Checks Before the Housing Closes
Three checks happen while the drivetrain is still accessible. None of them repeat once the covers go on.
Belt tension comes from measurement rather than feel. We use the frequency of the free span. Tension governs the axial stiffness of a belt axis, so an under-tensioned belt produces lost motion that looks like a control fault during commissioning. Our page on belt linear module accuracy sets out the calculation behind the target value.
Shaft end runout goes on a dial indicator while the shaft turns. Radial runout at the drive end flexes the coupling once per revolution. That injects a periodic disturbance into the position loop, and it loads the support bearings in a direction nobody sized them for.
Lubrication gets verified rather than assumed. We confirm that grease has travelled through the port and reached the recirculating elements. An under-charged block gives no symptom at the bench, then wears early in service.
Belt tension measurement by span frequency Shaft end runout measurement Lubrication charge verification
Mechanical Integrity Before Final Assembly
Three further checks protect against faults that only appear after the module leaves us.
Fastener tightness covers every joint. A linear module is a fully reversing machine, and alternating load loosens fasteners that a static check would pass. This verification therefore carries more weight here than on a statically loaded assembly.
Cover-to-carriage clearance gets measured at several positions along the stroke rather than at one. A cover running too close drags on the carriage and adds friction that grows as the strip wears. One running too loose lets debris into the raceway. Uniformity along the travel matters more than the nominal figure.
Mounting hole patterns get inspected twice over. Standard patterns go back against the released drawing for that series. Customer patterns go back against the drawing that particular customer confirmed, which closes the loop opened during development when we issue 3D and 2D PDF drawings for written approval. A hole pattern is the one feature nobody can correct after despatch.
Fastener tightness check Cover-to-carriage clearance measurement

Mounting hole pattern inspection
Running Behaviour in Linear Module Quality Control
Static measurement describes the axis at rest. These three checks describe what it does under power.
Running smoothness gets checked with the motor mounting simulated rather than left open. Bolting a motor to the end block can pull the housing slightly out of shape. That loads the drivetrain against the rail, and the effect disappears whenever the mounting face is free. Checking under the mounted condition finds the resulting stiff spot at our bench, not during the customer’s commissioning.
Noise readings come from modules under power. We record both screw-driven units in the 100 frame size and belt-driven units in the 135 frame size, because the two structures fail differently and their normal signatures do not resemble each other. A change in noise makes a useful early indicator. On a belt axis a rise usually traces back to preload or alignment rather than to the belt itself.
Vibration readings come from assembled combinations rather than single axes. A stacked assembly carries resonances that neither axis shows alone, because the upper axis becomes a mass on the compliance of the lower one.
Running smoothness check Smoothness check with motor mounting simulated Noise test, 100 frame screw and rail module
Noise test, 135 frame belt and rail module Noise test, 150 frame belt and rail module Vibration test on a combined multi-axis module
Finished-Axis Measurement by Laser Interferometer
We measure positioning accuracy on completed modules with a laser interferometer. Module and optics both sit on granite, so the measurement baseline holds still through the run.
The axis runs in both directions, and the sequence repeats. We follow the method ISO 230-2 sets out. That produces two separate numbers. Repeatability describes the scatter of return positions at one target. Travel deviation describes error accumulated across the full stroke. Reporting them separately matters. Repeatability binds an axis shuttling between fixed stations, while travel deviation binds an axis interpolating a path. Our guide to screw linear module selection explains how a screw axis reaches each figure.
![]() |
![]() |
Repeatability measurement by laser interferometer
Multi-Axis and Gantry Assemblies
Stacked axes bring a requirement single axes never face. Each axis may measure correctly on its own while the assembly still fails, because the angle between them decides the outcome.
We set and verify orthogonality on granite with the axes assembled, rather than calculating it from the individual results. Squareness error between a lower and an upper axis produces a path error that grows with distance from the origin. A small angular deviation therefore becomes a large positional one at the far corner of the work envelope.
Large gantry frames add a further stage. Span alignment between the two driven sides gets checked assembled. Parallelism error across the span turns into racking during motion, and it loads both drives unevenly.
![]() |
![]() |
Gantry frame accuracy inspection
Functional and Environmental Testing
- Load testing — the module runs under applied payload. This confirms that behaviour matches the rated condition rather than the bench condition.
- Ingress testing — we expose sealed variants to water. Covers, wipers and cable entries then prove they perform as designed.
- High and low temperature shock testing — modules cycle between temperature extremes. This reveals differential expansion between the aluminium housing and the steel rail and screw.
- Speed testing — linear motor axes run to their intended velocity. We then observe acceleration and settling behaviour rather than assuming it.
Load testing under applied payload Waterproof ingress testing
High and low temperature shock testing Speed testing of a linear motor
Cleaning and Final Inspection Before Despatch
We clean every module before packing. Cleaning removes machining residue, handling marks and any debris that could migrate into a raceway during transport.
The step carries extra weight for modules bound for clean environments. Particles introduced at our end become the customer’s problem at theirs. Final visual inspection happens at the same station, so the last person to handle the module also checks it.
Pre-despatch cleaning
Packaging Is the Last Linear Module Quality Control Stage
An axis that measures correctly at our bench can still arrive out of tolerance. Transport applies shock and vibration that no inspection stage simulates, and it applies them to a module nobody is watching. Packaging therefore belongs inside linear module quality control rather than after it.
Modules ship in shock-absorbing packaging that isolates the carriage and the drive end, since those are the parts that take a fall badly. Export orders go into crates built from multi-layer plywood rather than solid timber. Plywood is a processed material, which puts it outside the scope of ISPM 15. Solid wood packaging crossing a border has to be heat treated or fumigated and then marked; a plywood crate does not. That keeps a shipment out of the queue at customs, and plywood stays rigid enough to stack under load.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Cleaning and final inspection Shock-absorbing packaging Export plywood crate packing
Where This Sits Alongside Development
The checks above verify that a module matches its design. Linear module quality control does not decide what that design should be, and that separate work appears on our linear module design and R&D page.
The two functions share equipment and share findings. A recurring inspection result is a design signal. A deviation that keeps appearing at the same stage usually changes a housing section or a mounting interface, rather than tightening an inspection limit.
The inspection criteria themselves come from engineering. Drawings, dimensional inspection charts, rail and screw inspection sheets and tolerance management standards are issued at design release, and a controlled drawing revision carries them forward whenever a design changes. The whole system operates under an ISO 9001 quality management system, and modules carry CE marking including Machinery Directive conformity.
Linear Module Quality Control FAQ
What do you measure against?
Granite surface plates, at every dimensional station. A linear axis can only be measured against something flatter than itself, so the datum comes before the instrument.
Which method do you use for positioning accuracy?
The method set out in ISO 230-2: bidirectional travel with repeated runs, reported as two separate figures — repeatability at a target, and travel deviation across the stroke.
Is orthogonality measured or calculated?
Measured, on granite, with the axes assembled. Calculating squareness from individual axis results misses the error the assembly actually introduces.
Why check preload class on incoming rails?
Because preload is invisible from the outside and decides both stiffness and running friction. Two rails that look identical can carry different grades, and a mismatched pair on one module shares load unevenly for the rest of its life.
Do you issue an inspection report?
On request, yes. We issue an inspection report or a certificate of conformity against the order. Where a customer does not ask for one, the underlying records still exist: paper inspection sheets are filed for a year, and the scanned copies are kept permanently, so a question raised two years later can still be answered from the file.
Can we audit your inspection equipment?
Yes. Our equipment list is available for supplier audits on request.
Tell Us What Your Machine Is Sensitive To
Different machines fail on different characteristics. Some need repeatability at fixed stations; others need travel deviation across a path, or squareness at the far corner of a work envelope.
Tell us which characteristic yours depends on. We will confirm what linear module quality control can measure on your order, and against which reference. Want to check our manufacturing?
Linear Modules,Linear Motors,Electric Cylinders