Manufacturer of Linear Modules,Linear Motors,Electric Cylinders,Truss System!

Linear Motor Systems/Linear Motion/

  • Product Details

Want to select an ironcore linear motor?

Author: DeMing, Engineering Director | Published: 7th,Sept 2016 | Category: Linear Motor Systems

An ironcore linear motor produces thrust the short way. Current in the forcer coil meets the alternating field of a permanent magnet track, and the resulting force acts along the axis of travel — no screw, no belt, no coupling, no gearbox standing between the motor and the load.

TechMan supplies two families. TM-PMJ covers compact and mid-force axes from 68.3 N to 860.3 N continuous. TM-PMK covers heavier machines, reaching 4621 N continuous and 10166.2 N peak on the largest configuration. Both use a modular magnet track, so travel length is a matter of how many track segments the machine frame carries rather than how long a screw can be turned.

 Iron Core Flat Linear Motor

Item

Parameter

Continuous thrust 68.3 – 4621 N
Peak thrust up to 10166.2 N
Motor families TM-PMJ40/50/75/100, TM-PMK50/75/125/175
Magnetic pole pitch 20 mm (TM-PMJ), 42 mm (TM-PMK)
Nominal air gap 0.7 mm (TM-PMJ), 1 mm (TM-PMK)
Maximum DC bus voltage 600 VDC
Insulation / protection Class F / IP54
Configuration single forcer or multiple independent forcers on one track

How Ironcore Linear Motor produces thrust

iron core flat linear motor working principle showing forcer, electromagnetic coil, permanent magnets and iron back yoke

working principle schematic

The forcer carries copper windings around a laminated iron core. The track carries permanent magnets, alternating north and south, bonded to a steel back yoke that closes the magnetic circuit. The servo drive feeds commutated current into the windings; that current sits inside the track’s field, and the Lorentz interaction pushes the forcer along.

The iron core is what separates this family from an ironless motor. Iron concentrates flux in the gap, which is why a TM-PMJ or TM-PMK forcer of a given cross section produces the thrust it does. The same iron is also pulled toward the magnets, and that normal attraction — 0.4 kN at the small end of TM-PMJ, 16 kN on TM-PMK175-702-4621 — is carried entirely by the linear guides and the machine structure. It never appears at the load. Sizing the guide rails for it is not an afterthought; on the larger TM-PMK sizes it is the dominant structural load case.

Six elements make up a working axis:

Forcer — the moving coil and iron core assembly, bolted to the carriage.

Magnet track — stationary, built from standard segments.

Iron back yoke — supports the magnets and returns flux.

Linear guide — carries payload, moment loads and the full normal attraction.

Linear encoder — the motor has no rotor position to infer travel from, so position comes from a scale on the axis itself.

Servo drive and controller — closes the loop directly on the load.

An optional Hall sensor is listed on the TM-PMJ forcers for commutation and initialisation, depending on the drive architecture selected.

Series and parallel windings — why a longer coil can have a lower force constant

Read the TM-PMJ40 rows in sequence and something looks wrong. TM-PMJ40-176-131 has a force constant of 57.1 N/Arms. The longer TM-PMJ40-256-203 has 29 N/Arms. More coil, less force per amp.

It is not a typo. The two motors are wound differently. The 96 mm and 176 mm TM-PMJ40 coils are series-connected; the 256 mm coil is parallel-connected. A parallel winding halves the turns seen by the drive per phase branch, which halves both the force constant and the back-EMF constant, and doubles the current the motor will accept — 2.3 Arms continuous becomes 7 Arms. Thrust still goes up, because thrust is Kf × I and the current rises faster than the constant falls.

What this decides for you is the drive, not the motor. A series-wound motor asks for a low-current, higher-voltage drive. A parallel-wound motor of the same family asks for roughly three times the current at a given thrust and correspondingly less voltage headroom per metre per second of speed. Choosing the motor before checking the drive’s current rating is the usual way this goes wrong.

The winding of every configuration is given in the tables below.

TM-PMJ Ironcore Linear Motor series — technical data

Compact to mid-force. 20 mm pole pitch, 0.7 mm nominal air gap, magnet track in 80 / 200 / 400 mm segments.

Model

Winding Fcn (N) Fpk (N) Icn (Arms) Ipk (Arms) Kf (N/Arms) Ke (Vpk/(m/s)) Coil mass (kg)

Fa (kN)

TM-PMJ40-96-068 series 68.3 171 2.3 10 29.7 24.2 0.56 0.4
TM-PMJ40-176-131 series 131.3 340 2.3 10 57.1 46.6 0.99 0.8
TM-PMJ40-256-203 parallel 203 505 7 24 29 34.8 1.45 1.2
TM-PMJ50-96-109 series 109 271 2.3 10 47.4 38.7 0.70 0.7
TM-PMJ50-176-230 series 230 564 2.3 10 100 81.6 1.31 1.5
TM-PMJ50-256-352 parallel 352.1 920 7 24 50.3 62 1.90 2.1
TM-PMJ75-96-196 series 196 526 2.3 10 85.2 69.5 1.12 1.1
TM-PMJ75-176-381 parallel 381.6 1050 4.5 18 84.8 68.2 2.11 2.2
TM-PMJ75-256-598 parallel 598.5 1441 7 24 85.5 102.8 3.09 3.2
TM-PMJ100-96-281 series 281.3 775 2.3 10 122.3 99.8 1.55 1.6
TM-PMJ100-176-551 parallel 551.2 1550 4.5 18 122.5 98.4 2.95 3.2
TM-PMJ100-256-860 parallel 860.3 2134 7 24 122.9 152 4.32 4.8

Magnet track mass: TM-PMJ40 2.23 kg/m · TM-PMJ50 2.93 kg/m · TM-PMJ75 4.6 kg/m · TM-PMJ100 6.4 kg/m.

Coil mass is listed because it belongs in your moving mass calculation, not in a footnote. On a light TM-PMJ40 axis the forcer can be a third of everything that moves.

TM-PMK Ironcore Linear Motor series — technical data

Higher thrust, 42 mm pole pitch, 1 mm nominal air gap, magnet track in 168 / 252 / 420 mm segments.

Model

Winding Fcn (N) Fpk (N) Icn (Arms) Ipk (Arms) Kf (N/Arms) Ke (Vpk/(m/s)) Coil mass (kg)

Fa (kN)

TM-PMK50-114-131 series 131.1 288.4 4.8 14.4 27.3 22.1 1.65 0.4
TM-PMK50-198-250 series 250.8 551.8 4.8 14.4 52.3 42.3 2.75 0.8
TM-PMK50-366-501 parallel 501.6 1103.5 9.6 28.8 52.3 42.3 5.00 1.6
TM-PMK75-114-222 series 222.3 489.1 4.8 14.4 46.3 37.5 2.35 0.7
TM-PMK75-198-424 series 424.6 934.1 4.8 14.4 88.5 71.7 3.95 1.3
TM-PMK75-366-829 parallel 829 1823.8 9.6 28.8 86.4 69.9 7.30 2.7
TM-PMK75-534-1182 parallel 1182.5 2601.5 13.7 43.2 86.3 69.9 11.70 4.2
TM-PMK125-114-451 series 451 992.2 4.8 14.4 94 76.1 4.00 1.3
TM-PMK125-198-842 series 842 1852.4 4.8 14.4 175.4 142.1 7.00 2.7
TM-PMK125-366-1663 parallel 1663 3658.6 9.6 28.8 173.2 140.3 12.85 5.4
TM-PMK125-534-2526 parallel 2526 5557.2 13.7 43.2 184.4 149.3 19.50 8.1
TM-PMK175-366-2310 parallel 2310 5082 9.6 28.8 240.6 194.9 20.20 8.0
TM-PMK175-534-3466 parallel 3466 7625 13.7 43.2 253 204.9 28.00 12.0
TM-PMK175-702-4621 parallel 4621 10166.2 19.2 57.6 240.7 194.9 39.40 16.0

Magnet track mass: TM-PMK50 2.6 kg/m · TM-PMK75 4.8 kg/m · TM-PMK125 8.6 kg/m · TM-PMK175 15.2 kg/m.

At 39.4 kg, the TM-PMK175-702-4621 forcer is heavier than most of the payloads it will be asked to move. That figure goes into the acceleration calculation before anything else does.

Attraction per newton of thrust: the real difference between TM-PMJ and TM-PMK

Both families are iron core motors, so both attract. The useful question is how much attraction you take on for each newton of usable thrust, because that ratio is what your guide rails, mounting plate and base structure have to absorb.

Working it out from the tables above:

Item

Fa : Fcn

TM-PMJ series ≈ 5.4 : 1 to 6.5 : 1
TM-PMK series ≈ 2.9 : 1 to 3.6 : 1

A TM-PMJ50-96-109 gives 109 N of continuous thrust and pulls 700 N onto the rails — 6.4 N of attraction per newton of work. A TM-PMK175-702-4621 gives 4621 N and pulls 16 kN, which is 3.5 to 1. The larger pole pitch and deeper magnetic circuit of the TM-PMK series convert the same attraction into considerably more thrust.

Two practical consequences follow.

If an axis is force-limited and the structure is already stiff, TM-PMJ is compact and the attraction is manageable in absolute terms. If an axis is stiffness-limited — a long cantilever, a thin gantry beam, a mounting plate you cannot make thicker — a TM-PMK motor buys the same thrust at roughly half the normal load, and that can be the difference between a beam that holds its straightness under power and one that does not.

Note also that attraction enters the friction budget. Rolling friction on a recirculating ball guide is roughly 0.003 to 0.005 of the normal load; a 2.2 kN attraction adds around 7 to 11 N of continuous drag that has nothing to do with the payload and is present at every point in the stroke.

Checking speed against bus voltage

Thrust sizing tells you which motor. Back-EMF tells you whether it will reach the commanded speed.

The motor generates voltage in proportion to velocity through Ke. Once that generated voltage approaches the DC bus, the drive can no longer push current into the winding and thrust collapses. A first-order ceiling is:

vmax ≈ Ubus / Ke

With the catalogue’s 600 VDC maximum bus:

  • TM-PMK175-534-3466, Ke = 204.9 → about 9 m/s
  • TM-PMJ100-256-860, Ke = 152 → about 9 m/s
  • TM-PMJ75-96-196, Ke = 69.5 → about 6 m/s

This is a coarse figure. It ignores resistive drop across the winding, inductive reactance at speed, and the modulation scheme’s actual voltage utilisation, all of which pull the real ceiling down — plan on meaningfully less than the number above, and confirm against the drive you intend to use. What the calculation is good for is elimination: if the machine needs 3 m/s and the arithmetic says 2.9, that motor and bus combination is out before anyone builds anything.

The parallel-wound configurations are the ones to look at here. Parallel winding roughly halves Ke, which roughly doubles the speed ceiling at the same bus voltage — one more reason the winding column matters.

Magnet track, air gap and travel length

Travel comes from the track. TM-PMJ segments are 80, 200 and 400 mm; TM-PMK segments are 168, 252 and 420 mm. Segments butt together along the machine base to make whatever length the application needs, and the forcer’s own length is subtracted from the track length to give usable stroke.

The air gap is the tolerance that governs everything else: 0.7 mm nominal on TM-PMJ, 1 mm on TM-PMK. That gap is held not by the motor but by the linear guides, the flatness of the mounting surfaces and the straightness of the assembled track. A machined mounting datum, a checked rail parallelism and a measured track joint alignment are what keep the gap uniform over a multi-metre axis. Our approach to establishing those datums is set out on the linear module quality control page.

Track segments also carry weight — 15.2 kg/m on TM-PMK175 — which matters for base plate design and for handling during installation, since the magnets attract every steel tool in the vicinity.

Common electrical and mechanical specifications

 Items TM-PMJ

TM-PMK

Maximum coil temperature 100 °C 100 °C
Maximum DC bus voltage 600 VDC 600 VDC
Magnetic pole pitch 20 mm 42 mm
Nominal air gap 0.7 mm 1 mm
Coil lengths 96 / 176 / 256 mm 114 / 198 / 366 / 534 / 702 mm
Track segment lengths 80 / 200 / 400 mm 168 / 252 / 420 mm
Insulation class Class B Class B
Protection level IP00 IP00
Compliance RoHS · CE (EMC & LVD) RoHS · CE (EMC & LVD)

Continuous ratings are quoted for self-cooling at a 25 °C reference room temperature and depend on the heat-dissipation conditions of the installation. Resistance is measured with DC and includes a 0.3 m standard cable; inductance is measured at 1 kHz.

Protection. Both families carry IP54 sealing on the coil and magnet track, which covers airborne dust and splashing water from any direction. It does not cover jets, immersion, coolant under pressure, or washdown, and it is not a substitute for keeping ferrous debris out of the air gap — a swarf particle in a 0.7 mm gap is a mechanical problem, not an ingress one. Machines cutting or grinding steel still need a cover or bellows over the track.

CE test reports under the EMC and Low Voltage Directives are available on request.

Where this Ironcore Linear Motor fits

The case for a linear motor is not that it is newer than a ball screw. It is that three specific demands break screws and belts, and this architecture answers all three.

Cycle rate at short stroke. A machine indexing 50 mm every 300 ms spends its whole life in acceleration and reversal. A screw returns that energy through a nut, bearings and a coupling, all of which wear and all of which introduce lost motion at reversal. Direct thrust has no reversal interface, so repeatability at the reversal point does not drift as the hours accumulate.

Stroke length beyond what a screw will turn. Screw critical speed falls with the square of unsupported length, and lengthening the screw does not raise it. A magnet track has no rotating element, so a 4 m axis reaches the same speed as a 400 mm one. Web converting lines, panel handling beams and long metrology travels sit here.

More than one mover on one path. Because the track is passive, several forcers can share it, each with its own encoder and drive, each following a different profile. Station spacing becomes a software parameter rather than a mechanical one — useful where product size changes between runs, or where one station’s dwell time should not hold up the others.

In practice these motors turn up on battery electrode and cell handling axes, display and glass panel transfer beams, pharmaceutical and medical device assembly stations, probe and coordinate scanning axes in test and measurement equipment, recoater axes on additive manufacturing platforms, and registration axes on converting and printing lines. Where an axis needs the same direct drive but arrives as a complete assembly with rail and encoder already integrated, see our linear motor with embedded guide rail.

Selecting a TM-PMJ or TM-PMK Iron Core Flat Linear Motor

    1. Add up everything that moves. Carriage, fixture, workpiece, tooling, sensors, cable carrier — and the forcer itself. Coil mass is in the tables above for exactly this reason.
    2. Work out peak thrust. F = m·a for the inertial term, plus process force, plus friction, plus m·g·sin θ for any axis that is not horizontal. Include the attraction-driven friction described earlier; on a large TM-PMK it is not negligible.
    3. Work out RMS thrust over the full cycle and compare it with Fcn. Peak rating covers acceleration; the continuous rating is what the duty cycle has to live within thermally.
    4. Check speed against the bus using v ≈ Ubus/Ke, with margin.
    5. Check the guides and structure against Fa, not against the payload. This is the step most often skipped.
    6. Build the stroke from track segments and confirm forcer length against usable travel.
    7. Specify feedback. Repeatability, resolution, incremental or absolute, maximum scanning speed, interface. Final axis accuracy is set by the encoder, guide, structural stiffness, servo tuning and thermal state — never by the motor alone.

             8. Confirm cooling. The thermal dissipation constant Kthn in the catalogue lets you derate: for a given continuous power under the same mounting conditions as the catalogue reference, temperature rise scales as P/Kthn. A motor bolted to a small isolated bracket will not reach its catalogue continuous rating.

Worked example

A horizontal pick-and-place axis. Carriage, tooling and workpiece total 10 kg. Target acceleration 20 m/s², 30 % of the cycle spent accelerating or decelerating, no significant process force.

Try TM-PMJ75-96-196. Forcer mass 1.12 kg, so the moving mass is 11.12 kg.

  • Inertial force: 11.12 × 20 = 222 N
  • Attraction 1.1 kN plus payload weight ≈ 1209 N normal load; at μ ≈ 0.004 that is ≈ 5 N of drag
  • Peak demand ≈ 227 N against Fpk = 526 N ✓
  • RMS thrust ≈ 222 × √0.3 + 5 ≈ 127 N against Fcn = 196 N ✓
  • Speed ceiling: 600 / 69.5 ≈ 8.6 m/s, far above anything this axis needs ✓
  • Current: 127 / 85.2 ≈ 1.5 Arms continuous, 2.7 Arms peak — a modest drive ✓

The motor is comfortable. If the payload later grows to 25 kg, the inertial term reaches 520 N and TM-PMJ75-96-196 runs out of continuous headroom; TM-PMJ75-176-381 is the next step, at the cost of a 2.11 kg forcer and 2.2 kN of attraction.

Dimensions of TM Ironcore Linear Motor

TM-PMJ dimensional drawing. 

TM-PMJ dimensional drawing

TM-PMK dimensional drawing.

TM-PMK high thrust iron core linear motor dimensions

TM-PMJ forcer of TM ironcore flat linear motor

Model

A W1 H W3 × N1 T × N

M

TM-PMJ40-96-068 96 40 38.8 15 × 1 32 × 2 M4 deep 4
TM-PMJ40-176-131 176 40 38.8 15 × 1 32 × 4 M4 deep 4
TM-PMJ40-256-203 256 40 38.8 15 × 1 32 × 7 M4 deep 4
TM-PMJ50-96-109 96 50 38.8 20 × 1 32 × 2 M4 deep 4
TM-PMJ50-176-230 176 50 38.8 20 × 1 32 × 4 M4 deep 4
TM-PMJ50-256-352 256 50 38.8 20 × 1 32 × 7 M4 deep 4
TM-PMJ75-96-196 96 75 38.8 20 × 2 32 × 2 M4 deep 4
TM-PMJ75-176-381 176 75 38.8 20 × 2 32 × 4 M4 deep 4
TM-PMJ75-256-598 256 75 38.8 20 × 2 32 × 7 M4 deep 4
TM-PMJ100-96-281 96 100 38.8 20 × 3 32 × 2 M4 deep 4
TM-PMJ100-176-551 176 100 38.8 20 × 3 32 × 4 M4 deep 4
TM-PMJ100-256-860 256 100 38.8 20 × 3 32 × 7 M4 deep 4

Two Ø5H7 locating pin holes are provided on the forcer mounting face. Hall sensor mounting is optional.

TM-PMJ magnet track of TM ironcore flat linear motor

Model

L W W2 B C × N2

Q

TM-PMJ40-L80-S / L200-S / L400-S 80 / 200 / 400 40 31 20 40 × 1 / 4 / 9 M4 countersunk
TM-PMJ50-L80-S / L200-S / L400-S 80 / 200 / 400 50 41 20 40 × 1 / 4 / 9 M4 countersunk
TM-PMJ75-L80-S / L200-S / L400-S 80 / 200 / 400 75 65 20 40 × 1 / 4 / 9 M4 countersunk
TM-PMJ100-L80-S / L200-S / L400-S 80 / 200 / 400 100 91 20 40 × 1 / 4 / 9 M4 countersunk

TM-PMK forcer of TM ironcore flat linear motor

Model A W1 H W3 × N1 T × N

M

TM-PMK50-114-131 114 53 61.1 20 × 1 28 × 2 M5 deep 5.5
TM-PMK50-198-250 198 53 61.1 20 × 1 28 × 5 M5 deep 5.5
TM-PMK50-366-501 366 53 61.1 20 × 1 28 × 11 M5 deep 5.5
TM-PMK75-114-222 114 75 61.1 40 × 1 28 × 2 M5 deep 5.5
TM-PMK75-198-424 198 75 61.1 40 × 1 28 × 5 M5 deep 5.5
TM-PMK75-366-829 366 75 61.1 40 × 1 28 × 11 M5 deep 5.5
TM-PMK75-534-1182 534 75 61.1 40 × 1 28 × 17 M5 deep 5.5
TM-PMK125-114-451 114 125 61.1 45 × 2 28 × 2 M5 deep 5.5
TM-PMK125-198-842 198 125 61.1 45 × 2 28 × 5 M5 deep 5.5
TM-PMK125-366-1663 366 125 61.1 45 × 2 28 × 11 M5 deep 5.5
TM-PMK125-534-2526 534 125 61.1 45 × 2 28 × 17 M5 deep 5.5
TM-PMK175-366-2310 366 180 64.1 45 × 3 28 × 11 M5 deep 5.5
TM-PMK175-534-3466 534 180 64.1 45 × 3 28 × 17 M5 deep 5.5
TM-PMK175-702-4621 702 180 64.1 45 × 3 28 × 23 M5 deep 5.5

TM-PMK magnet track

Model

L W W2 B C × N2

Q

TM-PMK50-L168-S / L252-S / L420-S 168 / 252 / 420 53 40 21 42 × 3 / 5 / 9 M4 countersunk
TM-PMK75-L168-S / L252-S / L420-S 168 / 252 / 420 75 62 42 84 × 1 / 2 / 4 M5 countersunk
TM-PMK125-L168-S / L252-S / L420-S 168 / 252 / 420 125 112 42 84 × 1 / 2 / 4 M5 countersunk
TM-PMK175-L168-S / L252-S / L420-S 168 / 252 / 420 180 165 42 84 × 1 / 2 / 4 M6 countersunk

All dimensions in mm.

FAQ about Ironcore Linear Motor 

Why does a longer coil sometimes have a lower force constant?

Because it is wound in parallel rather than in series. TM-PMJ40-176-131 is series-wound at 57.1 N/Arms; TM-PMJ40-256-203 is parallel-wound at 29 N/Arms but accepts 7 Arms instead of 2.3, so it delivers more thrust. The winding type is listed for every configuration in the tables above, and it determines the drive current rating you need.

What is the forcer mass of ironcore flat linear motor?

It ranges from 0.56 kg on TM-PMJ40-96-068 to 39.4 kg on TM-PMK175-702-4621. Every value is in the technical tables, because the forcer is part of the moving mass.

How do I read a TM-PMJ or TM-PMK model code?

Three fields: family and width class, coil length in mm, then continuous thrust in newtons. TM-PMJ100-256-860 is a 100 mm-wide TM-PMJ with a 256 mm coil producing 860 N continuous. TM-PMK175-702-4621 is a 180 mm-wide TM-PMK with a 702 mm coil producing 4621 N. The thrust field is rounded, so read the tables for the exact value.

What limits top speed on a 600 VDC bus?

Back-EMF. The winding generates roughly Ke volts per metre per second, and once that approaches the bus the drive can no longer force current in. Ubus/Ke gives about 2.9 m/s for TM-PMK175-534-3466 and about 8.6 m/s for TM-PMJ75-96-196 — before subtracting resistive drop, inductive reactance and modulation losses, all of which lower it further.

How much attraction force will the guides see?

Between 0.4 kN and 4.8 kN across TM-PMJ, and up to 16 kN on TM-PMK. Per newton of continuous thrust that works out at roughly 5.4–6.5 : 1 for TM-PMJ and 2.9–3.6 : 1 for TM-PMK, which is the number to design the rails and mounting plate against.

Which track segments do I combine for my stroke?

TM-PMJ segments are 80, 200 and 400 mm; TM-PMK segments are 168, 252 and 420 mm. Add segments to reach the track length, then subtract the forcer length (96–256 mm on TM-PMJ, 114–702 mm on TM-PMK) plus your overtravel allowance to get usable stroke.

What does the IP54 rating cover, and what does it not?

Dust ingress and splashing water, on both the coil and the magnet track. It does not cover pressurised coolant, jets, immersion or washdown, and it says nothing about ferrous swarf, which is a gap-clearance problem rather than a sealing one. Machines producing steel chips need a physical cover over the track regardless of the IP rating.

Can several forcers run on one track?

Yes, provided each has its own encoder, drive and control axis, and the mechanical layout keeps them from colliding.

What positioning accuracy will the axis of this ironcore flat linear motor achieve?

That depends on the linear encoder, the guide, structural stiffness, servo tuning and thermal conditions — it is a property of the assembled axis, not of the motor. Tell us the target and we will specify the feedback and structure to reach it.

Discuss your axis with our engineers

Send us the numbers and we will come back with a motor, a track configuration and a view on the guide and structure:

moving mass · effective stroke · maximum velocity · acceleration · cycle profile and duty · mounting orientation · required repeatability · encoder preference · servo drive brand and bus voltage · available envelope · number of movers · thermal environment

Non-standard axes are quoted from 3D drawings returned in about three days; production runs 10–12 days after drawing confirmation.

Related: linear module design and video gallery · linear module quality control · linear motor with embedded guide rail.