Industrial Servo Electric Cylinder: TMC Series Configuration and Selection Guide
Author: DeMing, Engineering Director | Published: 10th,Sept 2026 | Category: Electric Cylinder
Two engineers can specify the same industrial servo electric cylinder — same thrust, same stroke, same repeatability — and end up with two units that will not fit the same machine. The difference is not the cylinder. It is the drive layout, the mounting code and the rod-end connector, and those three choices decide the installed envelope, the direction the load path runs and whether the rod is allowed to see side load at all.
The TMC series covers sixteen frames from TMC40 to TMC300, ≤50 kg to ≤60 T, with strokes to 3,000 mm and repeat positioning accuracy of ±0.02 mm or ±0.01 mm. This page is about how the frames are configured rather than what an electric cylinder is: drive layout, envelope arithmetic, lead selection, the eight mounting codes and the six rod-end connections.

Fold-drive TMC cylinder in section. The return drive gearbox and timing pulleys move the motor off the screw axis.
Direct Connection or Fold: the first decision
Every TMC frame is built in two drive layouts, and the model code carries the choice in its second field.
T — direct connection (in-line). The servo motor sits on the cylinder axis and drives the ball screw through a coupling. Cross-section stays at the frame size, and nothing projects sideways. The whole motor and gearbox length adds to the axial envelope.
R — fold drive (parallel). The motor sits alongside the cylinder body and drives the screw through a timing belt and a pair of pulleys, with a return drive gearbox at the tail. Axial length drops by most of the motor package; width or height grows by the motor and belt housing.
The published TMC300 dimensions put a number on the trade. In direct connection the overall length is stroke + 420 mm. In fold drive it is stroke + 320 mm. One hundred millimetres of axial length, bought with a motor package standing off the side of the tube.
Fold drive is further orientable. The motor can fold up, down, left or right relative to the cylinder body, which is usually what settles the choice when the Industrial Servo Electric Cylinder has to go into a frame that is tight in one plane and open in another.
T01 — direct connection, front flange |
|
Turning stroke into installed length
Working length follows a fixed relationship on every TMC Industrial Servo Electric Cylinder dimension drawing:
L1 = stroke S + P
P is a constant for the frame, and the overall unit length adds the tail dimensions P1, K and the motor or gearbox length L2 behind it. The P values below are read from the R01 and T01 front-flange drawings.
|
Frame |
P (mm) | Frame | P (mm) |
|
TMC40 |
85 | TMC115 | 150 |
|
TMC50 |
87 | TMC135 | 200 |
|
TMC60 |
85 | TMC140 |
275 |
| TMC75 | 104 | TMC160 |
300 |
| TMC80 | 120 (S ≤ 400) / 150 (S > 400) | TMC180 |
330 |
| TMC94 / TMC94Z | 130 | TMC245 |
330 |
Two points worth carrying into a layout drawing. TMC80 changes its P value at 400 mm of stroke, so a long-stroke TMC80 is 30 mm longer than the short-stroke arithmetic suggests. And P is tied to the mounting code as well as the frame — TMC50 reads 87 mm on the front-flange drawing and 101 mm on the front-face-mount drawing — so the envelope has to be taken from the drawing for the configuration actually being ordered.
TechMan Industrial Servo Electric Cylinder Technical Parameters
| Model | Thrust | Stroke
(mm) |
Cylinder Ø | Outline (mm) | Screw Ø | Screw lead (mm) | Max speed (mm/s) | Rod Ø | Repeatability (mm) |
| TMC40 | ≤50 kg | ≤300 | Ø30 | 40×40 | Ø12 | 4, 5 | 250 | Ø20 | ±0.02 / ±0.01 |
| TMC50 | ≤150 kg | ≤360 | Ø40 | 53×53 | Ø12 | 5, 10 | 500 | Ø25 | ±0.02 / ±0.01 |
| TMC60 | ≤270 kg | ≤480 | Ø50 | 61×61 | Ø16 | 5, 10, 16, 20 | 500 | Ø35 | ±0.02 / ±0.01 |
| TMC60Z | ≤500 kg | ≤480 | Ø50 | 61×61 | Ø16 | 5, 10, 16, 20 | 500 | Ø35 | ±0.02 / ±0.01 |
| TMC75 | ≤680 kg | ≤600 | Ø63 | 75×75 | Ø20 | 5, 10, 20 | 500 | Ø45 | ±0.02 / ±0.01 |
| TMC75Z | ≤800 kg | ≤600 | Ø63 | 75×75 | Ø20 | 5, 10, 20 | 500 | Ø45 | ±0.02 / ±0.01 |
| TMC80 | ≤2 T | ≤750 | Ø65 | 80×80 | Ø25 | 5, 10, 25 | 1000 | Ø50 | ±0.02 / ±0.01 |
| TMC94 | ≤2 T | ≤960 | Ø80 | 94×94 | Ø32 | 5, 10, 20, 32 | 1000 | Ø60 | ±0.02 / ±0.01 |
| TMC94Z | ≤3 T | ≤960 | Ø80 | 94×94 | Ø32 | 5, 10, 20, 32 | 1000 | Ø60 | ±0.02 / ±0.01 |
| TMC115 | ≤5 T | ≤1200 | Ø100 | 112×112 | Ø40 | 5, 10, 20, 40 | 250 | Ø75 | ±0.02 / ±0.01 |
| TMC135 | ≤10 T | ≤1500 | Ø120 | 134×134 | Ø50 | 10, 20 | 250 | Ø90 | ±0.02 / ±0.01 |
| TMC140 | ≤13 T | ≤1500 | Ø110 | Ø132 | Ø50 | 10, 20 | 250 | Ø90 | ±0.02 / ±0.01 |
| TMC160 | ≤18 T | ≤1800 | Ø140 | 158×158 | Ø63 | 20 | 250 | Ø100 | ±0.02 / ±0.01 |
| TMC180 | ≤20 T | ≤1800 | Ø160 | Ø180 | Ø63 | 20 | 250 | Ø120 | ±0.02 / ±0.01 |
| TMC245 | ≤40 T | ≤2400 | Ø180 | Ø210 | Ø80 | 20 | 250 | Ø140 | ±0.02 / ±0.01 |
| TMC300 | ≤60 T | ≤3000 | Ø220 | Ø280 | Ø100 | 20, 25 | 500 | Ø180 | ±0.02 / ±0.01 |
Loads above 60 T are handled as non-standard builds to a maximum of 100 T. Multi-stage cylinders are quoted case by case.
Motor and reducer options by frame
|
Model |
Motor flange |
Planetary reducer |
| TMC40 | 40 flange, 42 stepper | — |
| TMC50 | 40 / 60 flange, 57 stepper | — |
| TMC60 | 60 flange, 57 stepper | — |
| TMC60Z | 80 flange, 86 stepper | 60 flange |
| TMC75 | 60 / 80 flange, 86 stepper | — |
| TMC75Z | 100 / 130 flange | 60, 90 flange |
| TMC80 | 80 / 100 / 130 flange | 60, 90, 115 flange |
| TMC94 | 80 / 100 / 130 flange | — |
| TMC94Z | 180 flange | 85, 90, 115 flange |
| TMC115 | 130 / 180 flange | 115, 142 flange |
| TMC135 | 130 / 180 flange | 115, 142 flange |
| TMC140 | — | 142 flange |
| TMC160 | — | 142, 180 flange |
| TMC180 | — | 142, 180 flange |
| TMC245 | — | 180, 220 flange |
| TMC300 | — | 220 flange |
The Z variants are the geared members of a frame pair. TMC60 and TMC60Z share a body, a Ø16 screw and the same lead options; TMC60Z carries a larger motor through a 60-flange planetary reducer and reaches ≤500 kg against ≤270 kg. Frames from TMC140 upward are supplied through a reducer only.
Choosing the screw lead for TechMan Industrial Servo Electric Cylinder
Lead sets speed and thrust in opposite directions from the same motor. Linear speed is lead × screw speed, and thrust for a given motor torque falls as lead rises. On a TMC50 a 10 mm lead at 3,000 rpm gives the catalogue’s 500 mm/s; dropping to 5 mm halves the speed and roughly doubles the available thrust at the same torque.
Which limit binds changes as the frame grows.
- Small and mid frames (TMC40–TMC94Z) are motor-speed limited at short strokes. Once stroke grows, screw critical speed takes over as the ceiling, which is why a long-stroke unit will not reach the series maximum. The same critical-speed and DN reasoning applies here as on a ball screw linear module — see screw linear module selection.
- Heavy frames (TMC115 and above) are limited by the reduction needed to make the thrust. TMC115 offers a 40 mm lead and still tops out at 250 mm/s, because the planetary stage in front of the screw is doing the work.
Lead also sets resolution. Position resolution at the rod is lead divided by encoder counts per revolution and by any gear ratio in front of the screw, so a shorter lead buys fine positioning as well as thrust.
Mounting configurations: Fold drive mounting options in Industrial Servo Electric Cylinder
Eight mounting codes are published, each available in both drive layouts. The code follows the frame in the model number — TMC94-R01, TMC60-T04.
| Code | Mounting | What it does |
Frames (fold R / direct T) |
|
R01 Front flange |
|
Load path straight through the front face into the machine plate; rod stays coaxial with the bolt pattern |
R: TMC40–TMC300 T: TMC40–TMC300 |
|
R02 Rear flange |
|
Cylinder is carried from the tail, front face left clear |
R: TMC40–TMC140 |
|
R03 Trunnion |
![]() |
Pivot pins on the body sides, Ø12–Ø30, letting the cylinder swing through an arc |
R: TMC40–TMC94Z T: TMC40–TMC94 |
|
R04 Side flange |
![]() |
Bolt face parallel to the axis, for machines that only offer a side wall |
R: TMC40–TMC140 T: TMC40–TMC94Z |
|
05 Rear clevis |
|
Pin at the tail, Ø10–Ø70 by frame; pairs with a spherical rod eye at the front |
R: TMC40–TMC245 |
|
06 Guide rod type |
![]() |
External guide rods carry side load and stop the rod end rotating |
R: TMC40–TMC94 T: TMC40–TMC94Z |
|
R07 Front face mount (tapped holes) |
![]() |
Tapped front face, 4-M4 to 4-M10 by frame, in place of through-holes |
R: TMC40–TMC94 T: TMC40–TMC94 |
|
R08 Back-mounted |
Motor package carried over the body on the smallest frames |
R and T: TMC40, TMC50 |
One rule applies to all of them: the mounting hardware and the machine structure behind it must carry more than the maximum load the cylinder can generate, and the mass of the cylinder including its motor has to be counted in that figure. A cylinder that is rated for 3 T will apply 3 T to whatever is holding it.
R03 — rear trunnion |
|
Rod-end connection and rod thread for TechMan Industrial Servo Electric Cylinder
Six rod-end options connect the rod to the load: FM male thread (standard), BA female thread, P spherical rod eye, Y rod clevis, I rod eye, and TS for a machined custom rod end.
Rod end connection options
|
Code |
Image | Connection |
|
FM |
![]() |
Male thread (standard) |
|
BA |
![]() |
Female thread |
|
P |
![]() |
Spherical rod eye |
| Y | ![]() |
Rod clevis |
| I | ![]() |
Rod eye |
| TS | — |
Custom rod end (non-standard) |
The male rod thread is fixed by the frame, so the mating part can be designed before the cylinder is ordered.
|
Frame |
Rod thread | Frame |
Rod thread |
|
TMC40 |
M12 × 1.0 | TMC94 / 94Z / 115 | M40 × 1.5 |
|
TMC50 |
M16 × 1.5 | TMC135, TMC140 | M50 × 1.5 |
| TMC60 | M20 × 1.5 | TMC160, TMC180 |
M60 × 2.0 |
| TMC75, TMC80 | M30 × 1.5 | TMC245 |
M80 × 2.0 |
The choice is not only about the interface. A spherical rod eye or a rod clevis makes the cylinder a two-force member — it can only push and pull along a line between two pins, and any misalignment is taken up by the joints rather than by the rod. That is the configuration behind the R05 rear clevis, and it is the safest way to drive a load that moves through an arc.
Side load and the guide rod option
A rod-style cylinder resists axial force. It is not a linear guide. Radial force at the rod end loads the front bushing and the ball nut in a direction neither is built for, and the usual symptom is accuracy that decays long before the rated life is reached.
The guide rod configuration (R06 / T06) answers this by adding external guide rods between the front plate and a moving end plate, so the guide rods take the side load and the moment while the screw sees only thrust. Guide rod diameter runs Ø10 to Ø30 across TMC40 to TMC94Z, on centres of 70 to 160 mm. It also fixes rotation at the rod end, which matters whenever the tooling must stay square.
Where the load already runs in its own guide — a press ram in gibs, a slide on rails — a plain front-flange cylinder is the right answer and the guide rods are redundant mass.

R06 — guide rod type, fold drive
Where TechMan Industrial Servo Electric Cylinder is used
- Automotive and general manufacturing — car door hemming on welding lines, part stamping, and mould open-and-close drive on injection machines.
- Construction and engineering machinery — synchronised lift drives on powered stages, and boom extension on bridge inspection vehicles.
- Machine tools — ram position control on press brakes, and Z-axis lift on laser cutting machines.
- Logistics and warehousing — pusher mechanisms on sorters, and fork telescoping on AGVs.
- Consumer electronics and 3C — pressure control on phone screen lamination machines, the press mechanism in keyboard key life testers, and ejector pin drive on semiconductor packaging equipment.
The pattern across these is programmable force. A cylinder that can hold a commanded thrust while reporting position is doing something a pneumatic cylinder cannot, and it does it without a hydraulic power unit anywhere in the machine.

TMC series range, TMC40 to TMC300
Engineering support
Dimensional drawings for all eight mounting codes in both drive layouts are published for TMC40 through TMC300, including motor and reducer interface dimensions. Non-standard builds — custom rod ends, non-catalogue strokes, multi-stage cylinders, loads to 100 T — are returned as 3D models for confirmation before production.
Send us: stroke, thrust, duty cycle, mounting orientation, available envelope, and the motor brand if one is already specified.
- Request the TMC dimensional drawing set
- Ask for a configuration check on a stroke and load
- Discuss a non-standard build
FAQ about TechMan Industrial Servo Electric Cylinder
Which is shorter overall, a direct connection or a fold drive cylinder?
The fold drive. On TMC300 the direct connection unit measures stroke + 420 mm against stroke + 320 mm for the fold version. The fold drive spends that saving on width or height, since the motor and belt housing stand off one side of the body.
Can the rod take side load?
No. Radial load at the rod end goes into the front bushing and the ball nut. Where the load cannot be guided by the machine, specify the R06 or T06 guide rod configuration, which carries side load and moment on external guide rods.
What is the difference between TMC94 and TMC94Z?
Same body, same Ø32 screw, same lead options. The Z member takes a 180 flange motor through an 85, 90 or 115 flange planetary reducer and is rated ≤3 T against ≤2 T.
How do I work out the installed length before ordering?
L1 = stroke + P, with P read from the drawing for the frame and mounting code being ordered. Add the tail dimensions and the motor or gearbox length behind. Note that TMC80 changes P from 120 mm to 150 mm above 400 mm of stroke.
What determines the maximum speed I can actually reach?
On small and mid frames it is motor speed at short strokes and screw critical speed at long ones. On TMC115 and above it is the planetary reduction that produces the thrust — TMC115 offers a 40 mm lead and still caps at 250 mm/s.
Linear Modules,Linear Motors,Electric Cylinders










T01 — direct connection, front flange
R01 — fold drive (down), front flange




R05 — spherical rod eye with rear clevis